Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 1991

Value and limitations of proximal jet dimensions for the quantitation of valvular regurgitation: an in vitro study using Doppler flow imaging.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Baumgartner H, Schima H, Kühn P

Аннотация

To evaluate usefulness and limitations of proximal jet dimensions for the quantitation of valvular regurgitation, fluid jets were created in a pulsatile flow model, and proximal jet width and cross-sectional area were measured by means of color Doppler flow imaging. When circular orifices with diameters from 1 to 6 mm were studied, jet width and cross-sectional jet area measured as close as possible to the orifice were directly related to the orifice diameter (r = 0.97; standard error of the estimate, 0.4 mm; y = 0.5 + 0.97x) and the orifice area (r = 0.97; standard error of the estimate, 5.7 mm2; y = 0.22 + 2.47x), respectively. No significant dependence on flow rate or pressure gradient was found for these measurements. Jet width was measured with color M-mode Doppler by use of the smallest sample volume size (1 mm) and was slightly greater than the orifice diameter (4.2 +/- 1.7 mm versus 3.8 +/- 1.7 mm). However, cross-sectional areas were approximately fourfold the orifice areas, on average (52.5 +/- 24.6 mm2 versus 12.3 +/- 9.7 mm2), with a range of twelvefold (smallest orifice) to threefold (largest orifice). When the sample volume size was reduced from 2.4 to 1.0 mm, color areas decreased by 25.6 +/- 6.0%. Slit-shaped orifices were studied with two different orientations of the slit-parallel and perpendicular to the ultrasound beam: Color M-mode measurements were again slightly greater than length and width of the slit, but cross-sectional areas were substantially larger than the orifice areas and increased between 44% and 115% when changing the orientation of the slit from perpendicular to parallel. This, again, reflected problems with lateral resolution. When cross-sectional areas were measured at increasing distances from the orifice, the cross-sectional jet area increased significantly within a few millimeters. This increase was greater with higher gradients and smaller orifice sizes. In case of a small orifice (2 mm) and a high gradient (130 to 160 mm Hg), increase in area was as great as 122% within a distance of only 5 mm. Thus, proximal jet width and cross-sectional area were directly related to the orifice size, which could be a valuable parameter for the evaluation of valvular regurgitation. Measurements of jet width by color M-mode seemed to be most accurate but are limited by the fact that in vivo valvular defects may be irregular rather than of circular shape.(ABSTRACT TRUNCATED AT 400 WORDS)

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты