m+Medelevator.RU
← Поиск публикаций
BMC pulmonary medicine · 2020

Combination of 1.1 mm flexible cryoprobe with conventional guide sheath and therapeutic bronchoscope in biopsy of apical upper lobe solitary pulmonary nodule.

Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kho Sze Shyang, Chai Chan Sin, Nyanti Larry Ellee, Ismail Adam Malik Bin, Tie Siew Teck

Аннотация

BACKGROUND: Lung cancer is frequently situated peripherally in the upper lobes of the lung. Acquiring adequate tissue from this difficult-to-reach area remains a challenge. Transbronchial cryobiopsy (TBCB) has the ability to acquire larger specimens, but the rigidity of the standard 1.9 mm and 2.4 mm cryoprobes frequently poses challenges when used with a guide sheath (GS). The novel 1.1 mm cryoprobe, being both smaller and more flexible, may address this limitation. We describe the usage of this 1.1 mm flexible cryoprobe with GS in the biopsy of solitary pulmonary nodules (SPN) in the apical segment of the upper lobe in two cases.

CASE REPORT: Both procedures were conducted with advanced airway under total intravenous anaesthesia. 2.6 mm GS was used in combination with a 2.2 mm rEBUS probe, using a therapeutic bronchoscope. Case 1 describes a SPN in the apical segment of the right upper lobe that was inconclusive by forceps biopsy due to GS displacement and inadequate biopsy depth. A steerable GS combined with the novel cryoprobe subsequently overcame this issue. Case 2 describes a SPN in the apical segment of the left upper lobe in which the standard cryoprobe failed to advance through the GS due to steep angulation. It also highlights with shorter activation time, the novel cryoprobe enable biopsied tissue to be retrieved through the GS while the bronchoscope-GS remains wedgend in the airway segment. There were no bleeding or pneumothorax complications in both cases, and histopathological examination confirmed adenocarcinoma of the lung.

CONCLUSION: The 1.1 mm flexible cryoprobe in combination with GS and therapeutic bronchoscope offers an option to acquire adequate tissue in difficult-to-reach regions in the lung such as the apical segment of upper lobes. Further prospective series to evaluate its performance and safety in SPN biopsy is highly anticipated.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты