Computed tomography fluoroscopy-guided cutting needle biopsy of pulmonary nodules ≤8 mm: A retrospective study including 117 nodules.

Zhao Yanqing, Matsui Yusuke, Hiraki Takao, Iguchi Toshihiro, Tomita Koji, Uka Mayu, Gobara Hideo, Toyooka Shinichi, Kanazawa Susumu

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the diagnostic yield and safety of computed tomography (CT) fluoroscopy-guided cutting needle biopsy (CNB) for pulmonary nodules ≤ 8 mm.

METHOD: Data of CT fluoroscopy-guided CNB for pulmonary nodules ≤ 8 mm performed in a single institution were retrospectively analyzed. One hundred and seventeen biopsy procedures for 117 pulmonary nodules (mean size, 7.4 mm) in 114 patients were included in the study. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall diagnostic accuracy were calculated. Univariate analyses were performed to elucidate the risk factors for diagnostic failure (i.e., non-diagnostic, false-positive, or false-negative results). Complications were graded per the Clavien-Dindo Classification.

RESULTS

One (0.9 %) non-diagnostic biopsy result was found. The diagnostic accuracy was 95.7 % (112/117). The sensitivity and specificity were 95.8 % (91/95) and 95.5 % (21/22), respectively. PPV and NPV were 98.9 % (91/92) and 87.5 % (21/24), respectively. Univariate analyses showed that nodules in the lower lobes (p = 0.006) and prone biopsy position (p = 0.021) were the significant risk factors for diagnostic failure. The incidence of pneumothorax requiring chest tube placement (Grade IIIa) was 6.8 % (8/117). No Grade IIIb or higher complications were observed.

CONCLUSION

CT fluoroscopy-guided CNB for pulmonary nodules ≤ 8 mm showed a high diagnostic yield without severe complications.

Для цитирования: Zhao Yanqing, Matsui Yusuke, Hiraki Takao, Iguchi Toshihiro, Tomita Koji, Uka Mayu, Gobara Hideo, Toyooka Shinichi, Kanazawa Susumu. Computed tomography fluoroscopy-guided cutting needle biopsy of pulmonary nodules ≤8 mm: A retrospective study including 117 nodules.. European journal of radiology. 2020. DOI: 10.1016/j.ejrad.2020.108903.