Clinica chimica acta; international journal of clinical chemistry · 2016
Enhanced liver fibrosis (ELF) score: Analytical performance and distribution range in a large cohort of blood donors.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Dellavance Alessandra, Fernandes Flávia, Shimabokuro Natália, Latini Flavia, Baldo Danielle, Barreto José Augusto, Marvulle Valdecir, Andrade Luis Eduardo, Ferraz Maria Lucia
Аннотация
BACKGROUND: The Enhanced Liver Fibrosis (ELF) is a serological score that includes hyaluronic acid (HA), tissue inhibitor of matrix metalloproteinases-1(TIMP-1), and aminoterminal propeptide of type III procollagen (PIIINP) and shows good performance for detecting liver fibrosis. There are few studies evaluating ELF's intra and inter-assay variation and stability of the samples. The influence of host variables, such as age, gender and body mass index (BMI) is also not well known. We determined ELF's analytical performance and possible influences of gender, age and BMI.
METHODS: The study included 958 healthy blood donors evaluated for age, gender, and BMI.
RESULTS: Mean ELF scores were significantly different between female (8.53±0.75) and male groups (8.76±0.76) and also according to age strata (p<0.001). For both genders, ELF significantly varied in individuals with BMI under 25 (p<0.001). Analytes remained stable after freezing/thawing cycles and intra- and inter-assay coefficients of variation were low.
CONCLUSIONS: ELF has appropriate precision and is quite robust, due to the high stability of the analytes in fresh and frozen samples. ELF's results are influenced by gender, age and BMI which should be taken into account when analyzing its results.
METHODS: The study included 958 healthy blood donors evaluated for age, gender, and BMI.
RESULTS: Mean ELF scores were significantly different between female (8.53±0.75) and male groups (8.76±0.76) and also according to age strata (p<0.001). For both genders, ELF significantly varied in individuals with BMI under 25 (p<0.001). Analytes remained stable after freezing/thawing cycles and intra- and inter-assay coefficients of variation were low.
CONCLUSIONS: ELF has appropriate precision and is quite robust, due to the high stability of the analytes in fresh and frozen samples. ELF's results are influenced by gender, age and BMI which should be taken into account when analyzing its results.