Journal of the American College of Cardiology · 2003
Mechanism of syncope in patients with positive adenosine triphosphate tests.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Donateo Paolo, Brignole Michele, Menozzi Carlo, Bottoni Nicola, Alboni Paolo, Dinelli Maurizio, Del Rosso Attilio, Croci Francesco, Oddone Daniele, Solano Alberto, Puggioni Enrico
Аннотация
OBJECTIVES: We prospectively evaluated the mechanism of syncope in patients with positive adenosine triphosphate (ATP) tests (defined as the induction of atrioventricular [AV] block with a ventricular pause >/=6 s after an intravenous bolus of 20 mg ATP).
BACKGROUND: Patients with unexplained syncope tend to have more positive ATP tests results than those without syncope.
METHODS: An implantable loop recorder (ILR) was inserted in 36 ATP-positive patients (69 +/- 10 years; 22 women; median of 6 syncopal episodes); 15 of them also had a positive response to tilt testing.
RESULTS: During the follow-up of 18 +/- 9 months, 18 patients (50%) had syncopal recurrence and 16 (44%) had an electrocardiographically documented episode: AV block (n = 3: paroxysmal in 2 and permanent in 1), AV block followed by sinus arrest (n = 1), sinus arrest (n = 5), sinus bradycardia <40 beats/min (n = 2), normal sinus rhythm (n = 2), sinus tachycardia (n = 1), rapid atrial fibrillation (n = 1), and ectopic atrial tachycardia (n = 1). Bradycardia was documented in a total of 11 cases (69%), and a long ventricular pause (4 to 29 s) was present in eight cases (50%). All three patients with ILR-documented AV block had previously had a negative tilt test, whereas seven of eight with ILR-documented sinus bradycardia or sinus arrest had previously had a positive tilt test.
CONCLUSIONS: In patients with adenosine-sensitive syncope, the mechanism of syncope is heterogeneous, although bradycardia is the most frequent finding. Adenosine triphosphate-induced AV block predicts AV block as the mechanism of spontaneous syncope in only a few tilt-negative patients.
BACKGROUND: Patients with unexplained syncope tend to have more positive ATP tests results than those without syncope.
METHODS: An implantable loop recorder (ILR) was inserted in 36 ATP-positive patients (69 +/- 10 years; 22 women; median of 6 syncopal episodes); 15 of them also had a positive response to tilt testing.
RESULTS: During the follow-up of 18 +/- 9 months, 18 patients (50%) had syncopal recurrence and 16 (44%) had an electrocardiographically documented episode: AV block (n = 3: paroxysmal in 2 and permanent in 1), AV block followed by sinus arrest (n = 1), sinus arrest (n = 5), sinus bradycardia <40 beats/min (n = 2), normal sinus rhythm (n = 2), sinus tachycardia (n = 1), rapid atrial fibrillation (n = 1), and ectopic atrial tachycardia (n = 1). Bradycardia was documented in a total of 11 cases (69%), and a long ventricular pause (4 to 29 s) was present in eight cases (50%). All three patients with ILR-documented AV block had previously had a negative tilt test, whereas seven of eight with ILR-documented sinus bradycardia or sinus arrest had previously had a positive tilt test.
CONCLUSIONS: In patients with adenosine-sensitive syncope, the mechanism of syncope is heterogeneous, although bradycardia is the most frequent finding. Adenosine triphosphate-induced AV block predicts AV block as the mechanism of spontaneous syncope in only a few tilt-negative patients.