m+Medelevator.RU
← Поиск публикаций
American journal of nuclear medicine and molecular imaging · 2015

Influence of CT-based attenuation correction on dopamine transporter SPECT with [(123)I]FP-CIT.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lapa Constantin, Spehl Timo S, Brumberg Joachim, Isaias Ioannis U, Schlögl Susanne, Lassmann Michael, Herrmann Ken, Meyer Philipp T

Аннотация

Dopamine transporter (DAT) imaging using single-photon emission computed tomography (SPECT) and (123)I-labelled radiopharmaceuticals like [(123)I]FP-CIT is an established part in the diagnostic work-up of parkinsonism. Guidelines recommend attenuation correction (AC), either by a calculated uniform attenuation matrix (calAC) or by a measured attenuation map (nowadays done by low-dose CT; CTAC). We explored the impact of CTAC compared to conventional calAC on diagnostic accuracy and the use of DAT availability as a biomarker of nigrostriatal integrity.Integrated SPECT/CT studies with [(123)I]FP-CIT were performed in patients with Parkinson's disease (PD; n = 15) and essential tremor (ET; n = 15). SPECT data was reconstructed with calAC, CTAC and without AC (noAC). Regional DAT availability was assessed by uniform volume-of-interest analyses providing striatal binding potential (BP ND) estimates. BP ND values were compared among methods and correlated with clinical parameters. Compared to calAC, both CTAC and noAC provided significantly lower, but highly linearly correlated BP ND estimates (R (2) = 0.96). Diagnostic performance to distinguish between patients with PD and those with ET was very high and did not differ between AC methods. CTAC and noAC data tended so show a stronger correlation with severity and duration of disease in PD and age in ET than did calAC. Defining the reference region on low-dose CT instead of SPECT did not consistently alter findings. [(123)I]FP-CIT SPECT provides a very high diagnostic accuracy for differentiation between PD and ET that is not dependent on the employed AC method. Preliminary correlations analyses suggest that BP ND estimates derived from CTAC represent a superior biomarker of nigrostriatal integrity.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты