MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2025.112639

Медицинская библиотека · European journal of radiology · 2025

ChatGPT-5-Based large language model analysis versus an FDA-approved AI-CAD system for thyroid nodule ultrasound evaluation.

Chen Ziman, Ye Mengting, Liang Jieyi, Chen Fei, Ying Michael Tin Cheung

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: Recent advances in multimodal large language models (LLMs) have demonstrated promising potential for medical image analysis, yet their diagnostic capability in thyroid ultrasound remains unverified. This study explored the feasibility of ChatGPT-5, the latest multimodal LLM, for thyroid nodule classification and contextualized its diagnostic performance against S-Detect, an FDA-approved commercial computer-aided diagnosis system.

METHODS

In this prospective study, 141 patients with 186 nodules who underwent preoperative ultrasound and subsequent surgery were enrolled. For S-Detect, the largest transverse grayscale ultrasound image of each nodule was analyzed with automated contouring for binary classification. For ChatGPT-5, cropped transverse and longitudinal nodule ultrasound images were analyzed using a standardized diagnostic prompt for binary classification. Agreement with histopathology was assessed using Kappa statistics; sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve (AUC) were calculated.

RESULTS

Both systems showed statistically significant ability to distinguish benign from malignant nodules (P < 0.05). Agreement with histopathology was fair for ChatGPT-5 (Kappa = 0.224) and moderate for S-Detect (Kappa = 0.579). ChatGPT-5 demonstrated sensitivity 50.8 %, specificity 75.8 %, and accuracy 59.1 %, whereas S-Detect achieved higher sensitivity (91.9 %) and accuracy (82.3 %) but lower specificity (62.9 %). The AUC for S-Detect (77.4 %) was significantly greater than that for ChatGPT-5 (63.3 %, P < 0.001).

CONCLUSIONS

ChatGPT-5 demonstrated feasibility for thyroid nodule classification but showed lower diagnostic performance than the licensed, pre-trained S-Detect system and is not yet adequate for medical imaging applications.

Для цитирования: Chen Ziman, Ye Mengting, Liang Jieyi, Chen Fei, Ying Michael Tin Cheung. ChatGPT-5-Based large language model analysis versus an FDA-approved AI-CAD system for thyroid nodule ultrasound evaluation.. European journal of radiology. 2025. DOI: 10.1016/j.ejrad.2025.112639.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.