MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.125.015667

Медицинская библиотека · Circulation. Cardiovascular interventions · 2025

Transcatheter Valve Replacement in Adults With Congenital Heart Disease-The Mayo Clinic Experience.

Egbe Alexander C, Cabalka Allison K, Taggart Nathaniel W, Hagler Donald J, Eleid Mackram F, Rihal Charanjit S, Anderson Jason H

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The current study aims to describe outcomes after transcatheter valve replacement in adults with congenital heart disease.

METHODS

Retrospective study of adults with congenital heart disease who underwent transcatheter valve replacement and had a 1-year follow-up postintervention at Mayo Clinic (2010-2024). The study period was divided into early (2010-2014), mid (2015-2019), and late (2020-2024) eras. The primary outcome was valve reintervention. The secondary outcomes were all-cause mortality and temporal change in prosthetic valve gradient and clinical indices of disease severity.

RESULTS

Overall, 341 patients (age 38±17 years; 175 [51%] men) received 346 prostheses (pulmonary [N=236, 68%], tricuspid [N=75, 22%], aortic [N=22, 8%], and mitral [N=7, 2%]). The prostheses were Sapien (N=181, 52%), Melody (N=142, 41%), and Harmony prostheses (N=23, 7%). The number of transcatheter valve implantations increased from the early era (N=75), mid era (N=109), to the late era (N=162). The 10-year incidence of valve reintervention was 35%, and was similar between Sapien versus Melody prosthesis (41% versus 33%; P=0.11). The 10-year incidence of all-cause mortality was 13%. There was a temporal increase in prosthetic valve Doppler mean gradient (baseline versus 10 years) for pulmonary (12±5 versus 28±11 mmHg; P<0.001), tricuspid (3±1 versus 8±3 mmHg; P<0.001), and aortic prosthesis (13±5 versus 26±12 mmHg; P<0.001). There was a temporal increase in predicted peak oxygen consumption (absolute ∆, 9% [95% CI, 4-13]; P=0.006) and a decrease in NT-proBNP (N-terminal pro-B-type natriuretic peptide) level (absolute ∆, -138 pg/mL [95% CI, -209 to -64]; P<0.001) at 1-year postintervention.

CONCLUSIONS

There has been a temporal increase in the number of transcatheter valve implantations over time. Transcatheter valve replacement was associated with clinical improvement across multiple domains. However, there was a significant increase in prosthetic valve gradient within 10 years of follow-up, suggesting limited prosthesis longevity. There is a need for strategies to improve prosthetic valve longevity, which in turn may improve outcomes in this population.

Для цитирования: Egbe Alexander C, Cabalka Allison K, Taggart Nathaniel W, Hagler Donald J, Eleid Mackram F, Rihal Charanjit S, Anderson Jason H. Transcatheter Valve Replacement in Adults With Congenital Heart Disease-The Mayo Clinic Experience.. Circulation. Cardiovascular interventions. 2025. DOI: 10.1161/circinterventions.125.015667.