MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.13155

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2017

Pulmonary Vein Stenosis After Second-Generation Cryoballoon Ablation.

Matsuda Junji, Miyazaki Shinsuke, Nakamura Hiroaki, Taniguchi Hiroshi, Kajiyama Takatsugu, Hachiya Hitoshi, Takagi Takamitsu, Iesaka Yoshito, Hirao Kenzo, Isobe Mitsuaki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary vein stenosis (PVST) can occur after first-generation cryoballoon ablation. This study aimed to evaluate the incidence, severity, and characteristics of PVST after second-generation cryoballoon ablation.

METHODS

In total, 103 patients underwent PV isolation of paroxysmal atrial fibrillation using second-generation cryoballoons with a single big-balloon 3-minute freeze technique. Cardiac enhanced multidetector computed tomography (MDCT) was performed both before and a median of 6.0 (4.0-8.0) months after the procedure in all. PVST was classified as follows: minimal (<25%), mild (25-50%), moderate (50-70%), or severe (>70%).

RESULTS

In total, 406 PVs were analyzed. MDCT demonstrated PV stenosis in 10(2.5%) PVs among 8(7.8%) patients. In detail, minimal and mild PVSTs were observed in 6 and 4 PVs, respectively. PVST occurred in the left superior (LSPV), left inferior, and right superior PVs in 6, 1, and 3 PVs, respectively. No stenosis was observed in 15 PVs with active balloon deflations during freezing. All PVSTs had concentric patterns except for 2 PVs with minimal stenosis. Balloon deformities were observed during freezing of 2 PVs with mild stenosis. When the PVST was defined as a >25% decreased diameter, the incidence was 0.98% (4/406; including 3 LSPVs). PVST did not progress further during the follow-up period.

CONCLUSIONS

Although the incidence of PVST was low, it could occur even if a single big-balloon short freeze technique was applied. The risk of PV stenosis significantly differed among the 4 PVs, and reaching balloon temperatures of -60 °C and active balloon deflations during freezing were not associated with any PV stenosis.

Для цитирования: Matsuda Junji, Miyazaki Shinsuke, Nakamura Hiroaki, Taniguchi Hiroshi, Kajiyama Takatsugu, Hachiya Hitoshi, Takagi Takamitsu, Iesaka Yoshito, Hirao Kenzo, Isobe Mitsuaki. Pulmonary Vein Stenosis After Second-Generation Cryoballoon Ablation.. Journal of cardiovascular electrophysiology. 2017. DOI: 10.1111/jce.13155.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.