MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2016.12.014

Медицинская библиотека · Heart rhythm · 2016

Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-T trial.

Chun K R Julian, Stich Marie, Fürnkranz Alexander, Bordignon Stefano, Perrotta Laura, Dugo Daniela, Bologna Fabrizio, Schmidt Boris

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The ideal energy dosing remains unclear in second-generation cryoballoon (CB) pulmonary vein isolation (PVI). We aimed to investigate the effect of an individualized dosing strategy based on time to PVI (TTI).

OBJECTIVE

The purpose of this study was to prospectively investigate the safety and efficacy of individualized PVI using the second-generation CB guided by real-time pulmonary vein recordings.

METHODS

Two groups were prospectively randomized: ICE-T group: if TTI <75 seconds, then no bonus freeze; and control group: acute PVI followed by 1 empiric bonus freeze. Freeze duration was set to 240 seconds. The primary end point was single procedure sinus rhythm after 12 months (blanking period 3 months). Secondary end points included procedural data, complications, and biomarker release.

RESULTS

In total, 100 patients with paroxysmal atrial fibrillation were randomized. The primary end point was not different (88% vs 82%). Procedure and fluoroscopy times were significantly shorter in the ICE-T group (70 ± 20 minutes vs 89 ± 21 minutes; P < .001 and 10.6 ± 3.9 minutes vs 12.7 ± 5.5 minutes; P = .03). More complications occurred in the control group (n = 9 vs n = 3) (persistent phrenic nerve injury: n = 1 vs n = 0; transient phrenic nerve injury: n = 5 vs n = 2; esophageal lesions: n = 3 vs n = 1). Postablation troponin T levels were not different (ICE-T group vs control group: 1035 ± 402 ng/L vs 1219 ± 509 ng/L; P = .099), whereas a significantly lower lactic acid dehydrogenase release was observed in the ICE-T group (259 ± 47 U/L vs 282 ± 57 U/L; P = .038). Multivariate analysis identified a mean TTI of >43 seconds as the only independent predictor of recurrent atrial tachyarrhythmia.

CONCLUSION

The individualized CB PVI strategy allows faster atrial fibrillation ablation without affecting the favorable clinical outcome. A short TTI appears to predict freedom from recurrent atrial tachyarrhythmia.

Для цитирования: Chun K R Julian, Stich Marie, Fürnkranz Alexander, Bordignon Stefano, Perrotta Laura, Dugo Daniela, Bologna Fabrizio, Schmidt Boris. Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-T trial.. Heart rhythm. 2016. DOI: 10.1016/j.hrthm.2016.12.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.