MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-016-0189-3

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2016

Effect of left atrial volume and pulmonary vein anatomy on outcome of nMARQ™ catheter ablation of paroxysmal atrial fibrillation.

Stabile Giuseppe, Anselmino Matteo, Soldati Ezio, De Ruvo Ermengildo, Solimene Francesco, Iuliano Assunta, Sciarra Luigi, Bongiorni Maria Grazia, Calò Leonardo, Gaita Fiorenzo

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Left atrial volume (LA) and pulmonary vein (PV) anatomy may potentially relate to technical challenges in achieving stable and effective catheter position in case of atrial fibrillation (AF) ablation by means of "one-shot" catheters. The aim of this study was to investigate whether LA volume and PV anatomy, evaluated by computed tomography (CT) or magnetic resonance (MR) prior to ablation, predict acute and midterm outcome of AF ablation by nMARQ™.

METHODS

We included 75 patients (mean age 58 ± 11 years, 67 % male) with symptomatic paroxysmal AF. All patients underwent CT/MR scanning prior to catheter ablation to evaluate LA volume and PV anatomy. All the patients underwent PV isolation by nMARQ™, an open-irrigated mapping and radiofrequency (RF) decapolar ablation catheter. Ablation was guided by electroanatomic mapping allowing RF energy delivery in the antral region of PVs from ten irrigated electrodes simultaneously.

RESULTS

Mean LA volume was 75 ± 40 ml. A normal anatomy (4 PVs) was documented in 40 (53 %) patients and abnormal anatomy (common truncus or accessory PVs) in 35 patients. Mean procedural and fluoroscopy times were 94 ± 55 and 8 ± 5 min, respectively, without significant differences among patients with normal or abnormal anatomy (92 ± 45 vs 95 ± 64 min, p = 0.85 and 6 ± 3 vs 8 ± 4 min, p = 0.65, respectively). Mean ablation time was 14 ± 3 min, and 99 % of the targeted veins were isolated with a mean of 23 ± 5 RF pulses per patient. After a mean follow-up of 17 ± 8 months, 23 (31 %) patients had an atrial arrhythmia recurrence. Neither LA volume nor PV anatomy was a predictor of outcome.

CONCLUSIONS

LA volume and PV anatomy did not affect procedural data and outcome in patients who underwent PV isolation by an open-irrigated mapping and RF decapolar ablation catheter.

Для цитирования: Stabile Giuseppe, Anselmino Matteo, Soldati Ezio, De Ruvo Ermengildo, Solimene Francesco, Iuliano Assunta, Sciarra Luigi, Bongiorni Maria Grazia, Calò Leonardo, Gaita Fiorenzo. Effect of left atrial volume and pulmonary vein anatomy on outcome of nMARQ™ catheter ablation of paroxysmal atrial fibrillation.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2016. DOI: 10.1007/s10840-016-0189-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.