MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.65.12.30

Медицинская библиотека · Investigative ophthalmology & visual science · 2024

A New Retest-Stable Tortuosity Metric for Retinal Vessel Analyses.

Giesser Samuel David, Turgut Ferhat, Saad Amr, Sommer Chiara, Zhou Yukun, Wagner Siegfried Karl, Keane Pearse Andrew, Becker Matthias, Cabrera DeBuc Delia, Somfai Gábor Márk

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Existing retinal vessel tortuosity metrics lack standardization and retest reliability, hindering their clinical utility. Our study addresses this gap by introducing a novel metric, coined as the "vascular curvature index" (VCI), to enhance accuracy and consistency in biomarkers associated with medical conditions. We assess VCI's performance in terms of retest reliability in healthy subjects to transform early detection and monitoring approaches for various diseases.

METHODS

We recruited 44 patients for a single-session study, capturing fundus images before and after a five-minute break. Using AutoMorph, we generated vessel segmentation maps and evaluated retest reliability using multiple tortuosity metrics. The VCI was introduced and statistically compared to existing metrics. We performed a paired one-sided t-test to test for significantly improved retest reliability of our newly proposed metric. We analyzed distribution histograms, Fisher-Pearson coefficient of skewness, and correlation matrices for further insights.

RESULTS

VCI is the most retest-reliable metric, statistically surpassing other curvature metrics, except inverse spherical radius tortuosity. With a somewhat negatively distributed pattern (coefficient of skewness of -0.52), VCI exhibits the strongest correlation with the second most retest-reliable metric; inverse-radius-tortuosity (Pearson and Spearman correlation of 0.7 and 0.72, respectively). Its correlation with angle-tortuosity is lower (Pearson and Spearman correlation of 0.05 and 0.07, respectively).

CONCLUSIONS

The VCI emerges as a highly retest-reliable metric with a relatively normal distribution in healthy patients. Further investigation is warranted to evaluate its clinical performance in real-world applications, potentially influencing proactive healthcare interventions and personalized treatment decision-making.

Для цитирования: Giesser Samuel David, Turgut Ferhat, Saad Amr, Sommer Chiara, Zhou Yukun, Wagner Siegfried Karl, Keane Pearse Andrew, Becker Matthias, Cabrera DeBuc Delia, Somfai Gábor Márk. A New Retest-Stable Tortuosity Metric for Retinal Vessel Analyses.. Investigative ophthalmology & visual science. 2024. DOI: 10.1167/iovs.65.12.30.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.