MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbm.a.31713

Медицинская библиотека · Journal of biomedical materials research. Part A · 2008

Evaluation of the skin sensitizing potential of biodegradable magnesium alloys.

Witte Frank, Abeln Inken, Switzer Elinor, Kaese Volker, Meyer-Lindenberg Andrea, Windhagen Henning

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Corroding metals made of magnesium alloys represent a new class of degradable implants for musculoskeletal surgery. These implants may be associated with skin sensitizing reactions because of the release of metal ions. This study was conducted to compare the sensitizing potential of four different magnesium alloys (AZ31, AZ91, WE43, and LAE442) to current implant materials such as titanium (TiAl6V4) and a degradable polymer (SR-PLA96). Solutions and solid chips of these materials were prepared and tested in 156 guinea pigs according to the Magnusson-Kligman test. A standard allergen (hydroxy-cinnamon-aldehyde) causing allergic erythema was used as positive control and a standard irritant (sodium-lauryl-sulfate) causing local skin irritation for less than 24 h was used as negative control. All erythema were graded immediately and 24 h after patch removal by three independent observers. Histomorphological analyses were performed on skin biopsies taken 24 h after patch removal. We found that initial erythema in animals treated with solid chips diminished within 24 h and were caused by local skin irritation. Local skin irritation was also determined in erythema remaining for 24 h after patch removal in animals treated with dissolved test materials. No allergenic reactions according to the histomorphological criteria were observed in skin biopsies. We conclude that no skin sensitizing potential were detected for standard materials as well as for all tested magnesium alloys by the used methods.

Для цитирования: Witte Frank, Abeln Inken, Switzer Elinor, Kaese Volker, Meyer-Lindenberg Andrea, Windhagen Henning. Evaluation of the skin sensitizing potential of biodegradable magnesium alloys.. Journal of biomedical materials research. Part A. 2008. DOI: 10.1002/jbm.a.31713.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.