MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.122.3.1018

Медицинская библиотека · Chest · 2002

Influence of particle size on extrapleural talc dissemination after talc slurry pleurodesis.

Ferrer Jaume, Montes Juan F, Villarino Maria A, Light Richard W, García-Valero José

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Cases of acute respiratory failure reported after talc pleurodesis have raised concerns about its safety. It has been speculated that this pulmonary inflammatory syndrome is secondary to the extrapleural dissemination of the talc particles.

STUDY

OBJECTIVES

To test the hypothesis that particle size influences extrapleural talc deposition and pleural inflammation after talc slurry pleurodesis.

DESIGN

Thirty rabbits underwent pleurodesis as follows: 10 rabbits received 200 mg/kg of the talc used for human pleurodesis, normal talc (NT); 10 rabbits received 200 mg/kg of talc with particles of larger size, large talc (LT); and 10 rabbits received saline solution. Samples from the ipsilateral lung, chest wall, diaphragm, mediastinal pleura, heart, liver, spleen, and right kidney were obtained at 24 h and 7 days and processed for optic and electron microscopy and energy-dispersive x-ray analysis.

RESULTS

Visceral pleural thickening was greater with NT than with LT, but no differences were observed in the macroscopic score of adhesions. There was more talc in the lungs of the rabbits that received NT than in those that received LT. Talc particles were detected in mediastinum (100%) and pericardium (20%), irrespective of the talc used. Three animals, all receiving NT, had talc particles in the liver.

CONCLUSIONS

Our study shows that while both talcs were equally effective in achieving pleurodesis, the intrapleural injection of NT elicits greater pulmonary and systemic talc particle deposition than LT. Moreover, pleural inflammation was greater with NT than with LT.

Для цитирования: Ferrer Jaume, Montes Juan F, Villarino Maria A, Light Richard W, García-Valero José. Influence of particle size on extrapleural talc dissemination after talc slurry pleurodesis.. Chest. 2002. DOI: 10.1378/chest.122.3.1018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.