Binocular summation in visual evoked cortical potential in patients who have significantly different P100 peak latencies in their two eyes.

Mizota Atsushi, Hoshino Akiko, Adachi-Usami Emiko, Fujimoto Naoya

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine whether binocular summation in visual evoked cortical potential (VEP) is present in patients who have significantly different P100 peak latencies in their two eyes.

METHODS

Twelve patients with unilateral optic neuritis (ON) and 11 normal controls were studied. All of them had visual acuity of > or = 20/20 in both two eyes and good stereoacuity. Transient and steady-state VEPs were recorded with monocular and binocular pattern-reversal stimulation.

RESULTS

In normal controls, the binocular summation ratio was 1.05 with transient stimulation and 1.21 with steady-state stimulation, and in ON patients it was 1.19 and 1.30, respectively. In ON patients, the peak latency of P100 components was delayed significantly when the affected eye was stimulated, but with binocular stimulation the waveform was very similar to that when the fellow eye was stimulated.

CONCLUSION

Binocular summation of VECP is not present in ON cases with large differences in the peak latency between the two eyes even if they have good stereoacuity. Binocular summation may not be correlated with stereopsis in adults whose binocular function has already matured.

Для цитирования: Mizota Atsushi, Hoshino Akiko, Adachi-Usami Emiko, Fujimoto Naoya. Binocular summation in visual evoked cortical potential in patients who have significantly different P100 peak latencies in their two eyes.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2004. DOI: 10.1007/s00417-004-0899-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.