Japanese journal of radiology · 2026

AI achieves board-level performance on the Japan diagnostic radiology board examination through direct image interpretation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Miki Soichiro, Hirano Yuichiro, Nakao Takahiro, Yamagishi Yosuke, Hanaoka Shouhei, Nomura Yukihiro, Hamada Akiyoshi, Kanemaru Noriko, Miyo Rintaro, Takahashi Masumi Mizuki, Hosoi Reina, Yoshikawa Takeharu, Abe Osamu

Аннотация

PURPOSE: To evaluate text-only versus vision-enabled performance of late-2025 large language models (LLMs) on the Japan Diagnostic Radiology Board Examination (JDRBE) and compare model performance with newly board-certified radiologists.

MATERIALS AND METHODS: Image-based questions from the JDRBE 2021 and 2023–2025 were collected, and ground truth answers were determined by expert consensus. Four commercial multimodal LLMs were evaluated: Gemini 2.5 Pro (March 2025, baseline), Gemini 3 Pro, GPT-5.1, and Claude Opus 4.5 (all released in November 2025). Each question was answered with image input (“vision”) and without images (“text-only”). For the JDRBE 2025, subjective legitimacy of responses was independently rated by two radiologists using a five-point Likert scale, and low-rated responses were further analyzed by error type. Additional analyses on the JDRBE 2025 subset included image-shuffling and multi-run variability assessment (five runs). Model accuracies were also compared with those of five newly board-certified radiologists who passed the JDRBE 2025.

RESULTS: Gemini 3 Pro achieved the highest accuracy among all models, scoring 85.3% (279/327) in the vision condition and significantly outperforming its text-only accuracy (74.3%, P < 0.001). Gemini 2.5 Pro and Claude Opus 4.5 also improved with image input, whereas GPT-5.1 did not. For the JDRBE 2025, Gemini 3 Pro in the vision condition received the highest legitimacy ratings, and its accuracy (88%) was above the range observed in a reference group of five newly board-certified radiologists (65%–83%), but hallucination was still the most common error type. Image-shuffling analysis using the 2025 subset showed no performance gain in all models, supporting reliance on visual input. Multi-run variability analysis showed high agreement across runs.

CONCLUSION: Among late-2025 commercial LLMs, Gemini 3 Pro demonstrated board-level performance on the JDRBE through direct medical image interpretation.

SECONDARY ABSTRACT: The performance of vision-enabled large language models on the Japan Diagnostic Radiology Board Examination was evaluated. Among the models released in November 2025, Gemini 3 Pro demonstrated significant capabilities in direct medical image interpretation, achieving accuracy above that of a reference group of five newly board-certified radiologists.

SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11604-026-01983-x.