Tandem T:Slim X2 Insulin Pump Use in Clinical Practice Among Pregnant Individuals With Type 1 Diabetes: A Retrospective Observational Cohort Study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Nandam Neeharika, Thung Stephen, Venkatesh Kartik K, Gabbe Steven, Ma Jianing, Peng Jing, Dungan Kathleen, Buschur Elizabeth O
Аннотация
BACKGROUND: Insulin pump use is increasing in frequency among pregnant individuals with type 1 diabetes (T1D). Automated insulin delivery (AID) technologies have not been studied extensively in pregnancy.
METHOD: We present a retrospective case series of eight individuals with T1D who used the Tandem t:slim X2 insulin pump (Tandem Diabetes Care, Inc., CA, USA) during pregnancy. Weekly continuous glucose monitor and insulin pump data were analyzed from electronic medical records and data-sharing portals. Safety, glycemic control, and pregnancy outcomes were examined with both the control IQ (CIQ) and basal IQ (BIQ) algorithms.
RESULTS: Six CIQ and two BIQ users were studied. The mean glycated hemoglobin (A1C) during pregnancy was 6.1%, and the average time in pregnancy-recommended glycemic range (TIR; 63-140mg/dL) was 67.9%. There were no instances of diabetic ketoacidosis or severe hypoglycemia. CIQ users had a higher mean sensor glucose (127.6 mg/dL) compared to BIQ participants (118.4 mg/dL). However, the average time below range (<63 mg/dL) was 6.1% in BIQ participants compared to 1.5% in CIQ participants. CIQ participants used several strategies to achieve glycemic targets, including daytime use of sleep activity. An increased basal-to-bolus insulin ratio was negatively correlated with TIR (r=-0.415).
CONCLUSIONS: Tandem t:slim X2 insulin pumps were safely used during pregnancy in eight individuals with T1D, with variable success in achieving recommended glycemic targets. Further research is needed to understand differences in CIQ and BIQ use in pregnancy. AID device manufacturers must additionally develop further methods to target lower glucose for pregnant users.
METHOD: We present a retrospective case series of eight individuals with T1D who used the Tandem t:slim X2 insulin pump (Tandem Diabetes Care, Inc., CA, USA) during pregnancy. Weekly continuous glucose monitor and insulin pump data were analyzed from electronic medical records and data-sharing portals. Safety, glycemic control, and pregnancy outcomes were examined with both the control IQ (CIQ) and basal IQ (BIQ) algorithms.
RESULTS: Six CIQ and two BIQ users were studied. The mean glycated hemoglobin (A1C) during pregnancy was 6.1%, and the average time in pregnancy-recommended glycemic range (TIR; 63-140mg/dL) was 67.9%. There were no instances of diabetic ketoacidosis or severe hypoglycemia. CIQ users had a higher mean sensor glucose (127.6 mg/dL) compared to BIQ participants (118.4 mg/dL). However, the average time below range (<63 mg/dL) was 6.1% in BIQ participants compared to 1.5% in CIQ participants. CIQ participants used several strategies to achieve glycemic targets, including daytime use of sleep activity. An increased basal-to-bolus insulin ratio was negatively correlated with TIR (r=-0.415).
CONCLUSIONS: Tandem t:slim X2 insulin pumps were safely used during pregnancy in eight individuals with T1D, with variable success in achieving recommended glycemic targets. Further research is needed to understand differences in CIQ and BIQ use in pregnancy. AID device manufacturers must additionally develop further methods to target lower glucose for pregnant users.