MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a3301

Медицинская библиотека · AJNR. American journal of neuroradiology · 2012

Feasibility of intravenous flat panel detector CT angiography for intracranial arterial stenosis.

Jeon J S, Sheen S H, Hwang G J, Kim H C, Kwon B J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: I.v. FDCT angiography is an emerging technology for the detection of intracranial vascular disease. This study was conducted to determine the feasibility of i.v. FDCT in estimating major atherosclerotic intracranial arterial stenosis with DSA as the reference.

MATERIALS AND

METHODS

DSA and i.v. FDCT were performed simultaneously in patients with transient ischemic attack or acute cerebral infarction. The degree and length of stenosis were measured. The stenotic vessels were categorized into 4 groups by the grade of stenosis: normal (<30%), mild (30%-49%), moderate (50%-69%), or severe (>70%). The vessels of the normal group were excluded from analysis to reduce spectrum bias. Measurement of vessels was recorded by using an electric ruler by a qualified endovascular neurosurgeon and a neuroradiologist.

RESULTS

Eight hundred forty-two vessel segments in 69 patients were calculated. Mild (n = 56), moderate (n = 47) and severe stenosis (n = 46) groups were analyzed. I.v. FDCT had a sensitivity of 97.6%, specificity of 96.9%, and negative predictive value of 96.9% for detecting ≥50% stenosis and respective values of 91.9%, 98.2%, and 97.4% for depicting ≥70% stenosis. The difference of stenotic length between the 2 tests was not significant as an increase in the severity of stenosis (Spearman rank correlation test; r = -0.12, P = .13).

CONCLUSIONS

I.v. FDCT can be a feasible alternative as a noninvasive method for evaluating stenosis of the major intracranial arteries.

Для цитирования: Jeon J S, Sheen S H, Hwang G J, Kim H C, Kwon B J. Feasibility of intravenous flat panel detector CT angiography for intracranial arterial stenosis.. AJNR. American journal of neuroradiology. 2012. DOI: 10.3174/ajnr.a3301.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.