DOI 10.1016/j.ophtha.2011.12.040

Медицинская библиотека · Ophthalmology · 2012

The ocular pulse amplitude as a noninvasive parameter for carotid artery stenosis screening: a test accuracy study.

Knecht Pascal B, Menghini Moreno, Bachmann Lucas M, Baumgartner Ralf W, Landau Klara

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate a potential correlation between the ocular pulse amplitude (OPA; i.e., the intraocular pressure difference between the systolic and diastolic phases of the heartbeat) and the severity of carotid artery stenosis (CAS) and to test its role as a screening parameter for CAS during routine ophthalmic examination.

DESIGN

Test accuracy study.

PARTICIPANTS

Patients referred for color duplex ultrasound examination of the extra- and intracranial cerebral arteries were enrolled consecutively.

METHODS

We measured OPA on both eyes by dynamic contour tonometry. Multivariate analyses were performed with risk factors for CAS (age, total cholesterol, low-density lipoprotein, and triglycerides) to compare the diagnostic value of OPA measurements with other non- or minimally invasive screening parameters.

MAIN OUTCOME MEASURES: The difference between OPA measurements in patients with no (<50%) and patients with severe CAS (>70%) as well as the value of OPA measurements to predict the severity of CAS taking further risk factors of CAS into consideration.

RESULTS

One hundred thirty-four eyes of 67 patients (25 women, 42 men) with a mean age of 67±13 years (range, 25-87) were included. The means of the OPA values of those patients showing no CAS (<50%) differed significantly (P = 0.036) from those with a stenosis of ≥70%. The multivariate model produced a statistically significant odds ratio (0.46; P = 0.007) for CAS of ≥70%.

CONCLUSIONS

The results of the present study provide proof of principle that the OPA is reduced in patients with CAS and may be used as a noninvasive, inexpensive, readily available, and unconfounded screening parameter to detect CAS and possibly to reduce the incidence of stroke.

FINANCIAL DISCLOSURE(S): The authors have no proprietary or commercial interest in any of the materials discussed in this article.

Для цитирования: Knecht Pascal B, Menghini Moreno, Bachmann Lucas M, Baumgartner Ralf W, Landau Klara. The ocular pulse amplitude as a noninvasive parameter for carotid artery stenosis screening: a test accuracy study.. Ophthalmology. 2012. DOI: 10.1016/j.ophtha.2011.12.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.