BACKGROUND AND PURPOSE: Carotid artery stenting (CAS) is associated with the risk of periprocedural embolic events. The procedural risk may vary with plaque characteristics. We aimed at determining the impact of carotid plaque surface irregularity on the risk of cerebral embolism during CAS.

METHODS

Solid microembolic signals (MES) during CAS for symptomatic carotid stenosis were assessed by means of dual-frequency transcranial Doppler ultrasound. Study endpoint was the number of solid MES during CAS in 12 patients with irregular carotid stenosis compared to 12 matched patients with smooth carotid stenosis.

RESULTS

A total of 438 solid MES were detected. The cumulative number of solid MES was 329 in patients with irregular plaques and 109 in those with smooth plaques. The proportion of subjects in whom solid MES were detected was higher in the irregular plaque group (11/12) than in the smooth plaque group (5/12) (p = 0.030). The numbers of solid MES per CAS procedure and per hour of CAS procedure were both higher in patients with irregular plaques than in those with smooth plaques (p = 0.008 and 0.015, respectively).

CONCLUSIONS

Carotid plaque surface irregularity predicts solid cerebral embolism during stenting of symptomatic carotid artery stenosis.

Для цитирования: Rosenkranz Michael, Russjan Arkadiusz, Goebell Einar, Havemeister Stefanie, Thomalla Götz, Cheng Bastian, Beck Christoph, Krützelmann Anna, Fiehler Jens, Gerloff Christian. Carotid plaque surface irregularity predicts cerebral embolism during carotid artery stenting.. Cerebrovascular diseases (Basel, Switzerland). 2011. DOI: 10.1159/000328883.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.