Quantitative T*2-mapping based on multi-slice multiple gradient echo flash imaging: retrospective correction for subject motion effects.

Magerkurth Joerg, Volz Steffen, Wagner Marlies, Jurcoane Alina, Anti Sandra, Seiler Alexander, Hattingen Elke, Deichmann Ralf

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Numerous clinical and research applications for quantitative mapping of the effective transverse relaxation time T*(2) have been described. Subject motion can severely deteriorate the quality and accuracy of results. A correction method for T*(2) maps acquired with multi-slice multiple gradient echo FLASH imaging is presented, based on acquisition repetition with reduced spatial resolution (and consequently reduced acquisition time) and weighted averaging of both data sets, choosing weighting factors individually for each k-space line to reduce the influence of motion. In detail, the procedure is based on the fact that motion artifacts reduce the correlation between acquired and exponentially fitted data. A target data set is constructed in image space, choosing the data yielding best correlation from the two acquired data sets. The k-space representation of the target is subsequently approximated as linear combination of original raw data, yielding the required weighting factors. As this method only requires a single acquisition repetition with reduced spatial resolution, it can be employed on any clinical system offering a suitable sequence with export of modulus and phase images. Experimental results show that the method works well for sparse motion, but fails for strong motion affecting the same k-space lines in both acquisitions.

Для цитирования: Magerkurth Joerg, Volz Steffen, Wagner Marlies, Jurcoane Alina, Anti Sandra, Seiler Alexander, Hattingen Elke, Deichmann Ralf. Quantitative T*2-mapping based on multi-slice multiple gradient echo flash imaging: retrospective correction for subject motion effects.. Magnetic resonance in medicine. 2011. DOI: 10.1002/mrm.22878.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.