MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ruq.0000000000000677

Медицинская библиотека · Ultrasound quarterly · 2024

Comparison of Fibroscan, Shear Wave Elastography, and Shear Wave Dispersion Measurements in Evaluating Fibrosis and Necroinflammation in Patients Who Underwent Liver Biopsy.

Seyrek Sinan, Ayyildiz Hakan, Bulakci Mesut, Salmaslioglu Artur, Seyrek Fatmatuzzehra, Gultekin Burak, Cavus Bilger, Berker Neslihan, Buyuk Melek, Yuce Servet

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Our aim was to predict these stages of hepatic fibrosis and necroinflammation using measurements from two-dimensional shear wave elastography (2D-SWE), transient elastography (Fibroscan, TE), and shear wave dispersion (SWD).

MATERIALS AND

METHODS

In this prospectively designed study, chronic liver patients with nonspecific etiology whose biopsy was performed for up to 1 week were included. Two-dimensional SWE, SWD, and TE measurements were performed. The METAVIR and F-ISHAK classification was used for histopathological evaluation.

RESULTS

Two-dimensional SWE and TE were considered significant for detecting hepatic fibrosis. In distinguishing ≥F2, for 2D-SWE, area under the receiver operating characteristics (AUROC) was 0.86 (confidence interval [CI], 0.75-0.96) for the cutoff value of 8.05 kPa ( P = 0.003); for TE, AUROC was 0.79 (CI, 0.65-0.94) for the cutoff value of 10.4 kPa ( P < 0.001). No significance was found for TE in distinguishing ≥F3 ( P = 0.132). However, for 2D-SWE, a cutoff value of 10.45 kPa ( P < 0.001), with AUROC = 0.87 (CI, 0.78-0.97) was determined for ≥F3. Shear wave dispersion was able to determine the presence of necroinflammation ( P = 0.016) and a cutoff value of 15.25 (meter/second)/kiloHertz ([m/s]/kHz) ( P = 0.006) and AUROC of 0.71 (CI, 0.57-0.85) were calculated for distinguishing ≥A2. In addition, a cutoff value of 17.25 (m/s)/kHz ( P = 0.023) and AUROC = 0.72 (CI, 0.51-0.93) were found to detect severe necroinflammation. The cutoff value for SWD was 15.25 (m/s)/kHz ( P = 0.013) for detecting ≥A2 in the reversible stage of fibrosis (F0, F1, and F2), and AUROC = 0.72 (CI, 0.56-0.88).

CONCLUSIONS

Two-dimensional SWE and TE measurements were significant in detecting the irreversible stage and the stage that should be treated in hepatic fibrosis noninvasively. Shear wave dispersion measurements were significant in detecting necroinflammation noninvasively.

Для цитирования: Seyrek Sinan, Ayyildiz Hakan, Bulakci Mesut, Salmaslioglu Artur, Seyrek Fatmatuzzehra, Gultekin Burak, Cavus Bilger, Berker Neslihan, Buyuk Melek, Yuce Servet. Comparison of Fibroscan, Shear Wave Elastography, and Shear Wave Dispersion Measurements in Evaluating Fibrosis and Necroinflammation in Patients Who Underwent Liver Biopsy.. Ultrasound quarterly. 2024. DOI: 10.1097/ruq.0000000000000677.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.