MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2014.01.030

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2014

Detecting multiple lysosomal storage diseases by tandem mass spectrometry--a national newborn screening program in Taiwan.

Liao Hsuan-Chieh, Chiang Chuan-Chi, Niu Dau-Ming, Wang Chung-Hsing, Kao Shu-Min, Tsai Fuu-Jen, Huang Yu-Hsiu, Liu Hao-Chuan, Huang Chun-Kai, Gao He-Jin, Yang Chia-Feng, Chan Min-Ju, Lin Wei-De, Chen Yann-Jang

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Interest in lysosomal storage diseases in newborn screening programs has increased in recent years. Two techniques, fluorescence (4-MU) and tandem mass spectrometry (MS/MS) methods are frequently used. We report a pilot study of large scale newborn screening for Fabry, Pompe, Gaucher, and MPS I diseases by using the MS/MS method in Taiwan and compared the performance of the MS/MS with 4-MU methods.

METHODS

More than 100,000 dried blood spots (DBSs) were collected consecutively as part of the national Taiwan newborn screening programs. The enzyme activities were detected by the MS/MS method from a DBS punch. Mutation analysis was further performed for newborns with detected enzyme deficiency.

RESULTS

The DNA sequence analysis for suspected cases revealed 64 newborns with confirmed Fabry mutations, 16 were classified as infantile or late-onset Pompe disease, and 1 was characterized as Gaucher disease. The positive predict value increased from 4.0% to 7.1% in the Pompe study, and from 61.0% to 95.5% in the Fabry study by the MS/MS method compared to 4-MU assay.

CONCLUSIONS

The MS/MS method has been validated as a more specific, powerful and efficient tool than the 4-MU assay. It also provided a multiplex solution of newborn screening for lysosomal storage diseases.

Для цитирования: Liao Hsuan-Chieh, Chiang Chuan-Chi, Niu Dau-Ming, Wang Chung-Hsing, Kao Shu-Min, Tsai Fuu-Jen, Huang Yu-Hsiu, Liu Hao-Chuan, Huang Chun-Kai, Gao He-Jin, Yang Chia-Feng, Chan Min-Ju, Lin Wei-De, Chen Yann-Jang. Detecting multiple lysosomal storage diseases by tandem mass spectrometry--a national newborn screening program in Taiwan.. Clinica chimica acta; international journal of clinical chemistry. 2014. DOI: 10.1016/j.cca.2014.01.030.