Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2010
High-contrast PET of melanoma using (18)F-MEL050, a selective probe for melanin with predominantly renal clearance.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Denoyer Delphine, Greguric Ivan, Roselt Peter, Neels Oliver C, Aide Nicolas, Taylor Stephen R, Katsifis Andrew, Dorow Donna S, Hicks Rodney J
Аннотация
UNLABELLED: The aim of this study was to evaluate the novel probe (18)F-6-fluoro-N-[2-(diethylamino)ethyl] pyridine-3-carboxamide ((18)F-MEL050) for the imaging of primary and metastatic melanoma.
METHODS: PET using (18)F-MEL050 was performed in murine models of melanoma. The specificity of (18)F-MEL050 was studied by comparing its accumulation in pigmented B16-F0 allograft tumors with that of human amelanotic A375 xenografts using PET and high-resolution autoradiography. (18)F-MEL050 PET results were compared with (18)F-FDG PET, the current standard in melanoma molecular imaging. To test the ability of (18)F-MEL050 to assess the metastatic spread of melanoma, a murine model of lung metastasis was imaged by PET/CT, and results correlated with physical assessment of tumor burden in the lungs.
RESULTS: In pigmented B16-F0 grafts, (18)F-MEL050 PET yielded a tumor-to-background ratio of approximately 20:1 at 1 h and greater than 50:1 at 2 and 3 h. In the B16-F0 melanoma allograft model, tumor-to-background ratio was more than 9-fold higher for (18)F-MEL050 than for (18)F-FDG (50.9 +/- 6.9 vs. 5.8 +/- 0.5). No uptake was observed in the amelanotic melanoma xenografts. Intense uptake of (18)F-MEL050 was evident in metastatic lesions in the lungs of B16-BL6 tumor-bearing mice on PET at 2 h after tracer injection, with high concordance between (18)F-MEL050 accumulation on PET/CT and tumor burden determined at necroscopy.
CONCLUSION: (18)F-MEL050 has a rapid tumor uptake and high retention with specificity for melanin, suggesting great potential for noninvasive clinical evaluation of suspected metastatic melanoma.
METHODS: PET using (18)F-MEL050 was performed in murine models of melanoma. The specificity of (18)F-MEL050 was studied by comparing its accumulation in pigmented B16-F0 allograft tumors with that of human amelanotic A375 xenografts using PET and high-resolution autoradiography. (18)F-MEL050 PET results were compared with (18)F-FDG PET, the current standard in melanoma molecular imaging. To test the ability of (18)F-MEL050 to assess the metastatic spread of melanoma, a murine model of lung metastasis was imaged by PET/CT, and results correlated with physical assessment of tumor burden in the lungs.
RESULTS: In pigmented B16-F0 grafts, (18)F-MEL050 PET yielded a tumor-to-background ratio of approximately 20:1 at 1 h and greater than 50:1 at 2 and 3 h. In the B16-F0 melanoma allograft model, tumor-to-background ratio was more than 9-fold higher for (18)F-MEL050 than for (18)F-FDG (50.9 +/- 6.9 vs. 5.8 +/- 0.5). No uptake was observed in the amelanotic melanoma xenografts. Intense uptake of (18)F-MEL050 was evident in metastatic lesions in the lungs of B16-BL6 tumor-bearing mice on PET at 2 h after tracer injection, with high concordance between (18)F-MEL050 accumulation on PET/CT and tumor burden determined at necroscopy.
CONCLUSION: (18)F-MEL050 has a rapid tumor uptake and high retention with specificity for melanin, suggesting great potential for noninvasive clinical evaluation of suspected metastatic melanoma.
Предметные рубрики MeSH
AnimalsAutoradiographyCell Line, TumorCell Transformation, NeoplasticContrast MediaFemaleFluorine RadioisotopesFluorodeoxyglucose F18HumansKidneyMelaninsMelanomaMiceNeoplasm MetastasisNiacinamidePositron-Emission TomographyPyridinesSubstrate SpecificityTomography, X-Ray ComputedTransplantation, HomologousWhole Body Imaging