Cardiovascular engineering and technology · 2025
A Fully Automatic Pipeline of Identification, Segmentation, and Subtyping of Aortic Dissection from CT Angiography.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhuang Changjin, Wu Yanan, Qi Qianqian, Zhao Shuiqing, Sun Yu, Hou Jie, Qian Wei, Yang Benqiang, Qi Shouliang
Аннотация
PURPOSE: Aortic dissection (AD) is a rare condition with a high mortality rate, necessitating accurate and rapid diagnosis. This study develops an automated deep learning pipeline for identifying, segmenting, and Stanford subtyping AD using computed tomography angiography (CTA) images.
METHODS: This pipeline consists of four interconnected modules: aorta segmentation, AD identification, true lumen (TL) and false lumen (FL) segmentation, and Stanford subtyping. In the aorta segmentation module, a 3D full-resolution nnU-Net is trained. The segmented aorta's boundary is extracted using morphological operations and projected from multiple views in the AD identification module. AD identification is then performed using the multi-view projection data. For AD cases, a 3D nnU-Net is further trained for TL/FL segmentation based on the segmented aorta. Finally, a network is trained for Stanford subtyping using multi-view maximum density projections of the segmented TL/FL. A total of 386 CTA scans were collected for training, validation, and testing of the pipeline.
RESULTS: For AD identification, the method achieved an accuracy of 0.979. The TL/FL segmentation for TypeA-AD and Type-B-AD achieved average Dice coefficient of 0.968 for TL and 0.971 for FL. For Stanford subtyping, the multi-view method achieved an accuracy of 0.990.
CONCLUSION: The automated pipeline enables rapid and accurate identification, segmentation, and Stanford subtyping of AD using CTA images, potentially accelerating the diagnosis and treatment. The segmented aorta and TL/FL can also serve as references for physicians. The code, models, and pipeline are publicly available at https://github.com/zhuangCJ/A-pipeline-of-AD.git .
METHODS: This pipeline consists of four interconnected modules: aorta segmentation, AD identification, true lumen (TL) and false lumen (FL) segmentation, and Stanford subtyping. In the aorta segmentation module, a 3D full-resolution nnU-Net is trained. The segmented aorta's boundary is extracted using morphological operations and projected from multiple views in the AD identification module. AD identification is then performed using the multi-view projection data. For AD cases, a 3D nnU-Net is further trained for TL/FL segmentation based on the segmented aorta. Finally, a network is trained for Stanford subtyping using multi-view maximum density projections of the segmented TL/FL. A total of 386 CTA scans were collected for training, validation, and testing of the pipeline.
RESULTS: For AD identification, the method achieved an accuracy of 0.979. The TL/FL segmentation for TypeA-AD and Type-B-AD achieved average Dice coefficient of 0.968 for TL and 0.971 for FL. For Stanford subtyping, the multi-view method achieved an accuracy of 0.990.
CONCLUSION: The automated pipeline enables rapid and accurate identification, segmentation, and Stanford subtyping of AD using CTA images, potentially accelerating the diagnosis and treatment. The segmented aorta and TL/FL can also serve as references for physicians. The code, models, and pipeline are publicly available at https://github.com/zhuangCJ/A-pipeline-of-AD.git .