m+Medelevator.RU
← Поиск публикаций
Thyroid : official journal of the American Thyroid Association · 2010

Diagnosis of iodide transport defect: do we need to measure the saliva/serum radioactive iodide ratio to diagnose iodide transport defect?

Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fukata Shuji, Hishinuma Akira, Nakatake Nobuhiro, Tajiri Junichi

Аннотация

BACKGROUND: Iodide transport defect (ITD) is an infrequent condition associated with congenital dyshormonogenetic goiter due to mutations in the Na(+)/I(-) symporter (NIS) gene transmitted in an autosomal recessive manner. Herein, we describe a patient with ITD and discuss the features important for the diagnosis, focusing on whether or not measuring the saliva/serum radioactive iodide ratio is useful.

SUMMARY: A 42-year-old Japanese man attended our hospital in 2010. At that time, he had been off L-thyroxine for several months. He had no obvious mental retardation. His parents were cousins and his sister also had a goiter. Since thyroid dyshormonogenesis could not be ruled out, thyroid function tests, scintigraphy, and ultrasonography were performed. The results showed marked hypothyroidism with a high thyroglobulin level of 627 ng/mL. The results for thyroglobulin antibody and thyroid peroxidase antibody were both negative. Ultrasonography showed an enlarged thyroid gland. Neither the thyroid nor the salivary gland was visualized by (99m)TcO(4)(-) scintigraphy. Therefore, we performed genetic testing for the NIS gene without measuring the saliva/serum radioactive iodide ratio. A homozygous mutation, T354P, was identified in the NIS gene. On the basis of this finding, we could make the definitive diagnosis of ITD due to an NIS mutation.

CONCLUSIONS: We recommend confirming the presence of the thyroid by ultrasonography of the neck first and then performing (99m)TcO(4)(-) scintigraphy. If neither the salivary gland nor the thyroid is visualized, screening for NIS mutations should be undertaken. This approach obviates the need to undertake measurement of the saliva/serum radioactive iodide ratio to diagnose ITD.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049