MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000000253

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2014

Contrast sensitivity function after correcting residual wavefront aberrations during RGP lens wear.

Yang Bi, Liang Bo, Liu Longqian, Liao Meng, Li Qian, Dai Yun, Zhao Haoxin, Zhang Yudong, Zhou Yifeng

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the effect on the contrast sensitivity function (CSF) of correcting the residual wavefront aberrations in myopic and keratoconic subjects wearing rigid gas permeable (RGP) contact lenses.

METHODS

Seventeen eyes of 16 myopic subjects and 20 eyes of 19 keratoconic subjects were included in this study. All eyes were habitually corrected with RGP lenses. The residual aberrations of the RGP lens-wearing eyes were compensated by an adaptive optics (AO) system. The contrast sensitivities were measured through a 4-mm artificial pupil at spatial frequencies of 2, 4, 8, 16, and 32 cycles per degree (cpd) during RGP lens wear for the myopic and keratoconic groups, respectively. The CSF measurements were repeated with and without AO correction. Comparisons of contrast sensitivity at all spatial frequencies with and without AO correction were performed respectively for the myopic and keratoconic groups during RGP lens wear.

RESULTS

In the myopic RGP lens-wearing group, the differences in contrast sensitivity at each spatial frequency, with and without AO correction, were not significant (all p values > 0.05). In the keratoconic RGP lens-wearing group, the contrast sensitivities at all spatial frequencies with AO correction were higher than those without AO correction, but differences only at the low (2 cpd) and intermediate (4, 8, and 16 cpd) spatial frequencies were significant (p = 0.039, 0.005, 0.001, and 0.007).

CONCLUSIONS

The residual aberrations significantly reduced the contrast sensitivities at low and intermediate spatial frequencies for keratoconic RGP lens-wearing eyes but did not have any effect on the CSF for the myopic RGP lens-wearing eyes. Developing techniques that could more completely correct the wavefront aberrations may improve visual performance in keratoconus.

Для цитирования: Yang Bi, Liang Bo, Liu Longqian, Liao Meng, Li Qian, Dai Yun, Zhao Haoxin, Zhang Yudong, Zhou Yifeng. Contrast sensitivity function after correcting residual wavefront aberrations during RGP lens wear.. Optometry and vision science : official publication of the American Academy of Optometry. 2014. DOI: 10.1097/opx.0000000000000253.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.