Clinical evaluation of corneal biomechanical parameters after posterior chamber phakic intraocular lens implantation.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ali Mohamed, Kamiya Kazutaka, Shimizu Kimiya, Igarashi Akihito, Ishii Rie

Аннотация

PURPOSE: The aim of this study was to quantitatively assess the changes in corneal biomechanics after posterior chamber phakic intraocular lens (Visian ICL; STAAR Surgical) implantation for normal and keratoconic subjects.

METHODS: We retrospectively examined 29 eyes of 16 consecutive patients (mean age ± SD, 32.4 ± 7.3 years) undergoing implantable collamer lens (ICL) implantation through a 3.0-mm temporal corneal incision. We longitudinally assessed the values of corneal hysteresis (CH) and corneal resistance factor (CRF) using an Ocular Response Analyzer. We also investigated the relationship between these biomechanical parameters and central corneal thickness (CCT) preoperatively, and at 1 week, 1 month, and 3 months postoperatively.

RESULTS: The CH was 9.2 ± 1.4 mm Hg preoperatively, and 9.2 ± 1.4 mm Hg, 9.3 ± 1.7 mm Hg, and 8.8 ± 1.3 mm Hg at 1 week, 1 month, and 3 months postoperatively, respectively. The CRF was 8.4 ± 1.6 mm Hg preoperatively, and 9.0 ± 1.5 mm Hg, 8.8 ± 1.7 mm Hg, and 8.8 ± 1.6 mm Hg, at 1 week, 1 month, and 3 months postoperatively, respectively. Multiple comparisons demonstrated no significant differences between measurements made preoperatively and postoperatively (P > 0.05, Dunnett test). Both CH and CRF were significantly correlated with CCT 3 months postoperatively [Spearman correlation coefficient (r) = 0.48, P = 0.01 for CH; r = 0.84, P < 0.001 for CRF].

CONCLUSIONS: We found no significant changes in CH or CRF after ICL implantation, not only in normal eyes but also in keratoconic eyes, suggesting that this surgical technique does not significantly affect corneal biomechanical factors. The CCT may play some role in corneal biomechanics even in eyes undergoing ICL implantation.