m+Medelevator.RU
← Поиск публикаций
Investigative ophthalmology & visual science · 2014

Supersonic shear wave elastography for the in vivo evaluation of transepithelial corneal collagen cross-linking.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Touboul David, Gennisson Jean-Luc, Nguyen Thu-Mai, Robinet Antoine, Roberts Cynthia J, Tanter Mickael, Grenier Nicolas

Аннотация

PURPOSE: To assess corneal stiffening with supersonic shear wave imaging (SSI) technology in an experimental model of iontophoresis-assisted transepithelial corneal collagen cross-linking (I-CXL).

METHODS: Six rabbits underwent full, central I-CXL in one eye. The contralateral eye served as control. In vivo iontophoresis was used for 10 minutes to perform transepithelial delivery of riboflavin prior to UV-A irradiation. Accelerated UV-A protocol was applied for 9 minutes with a 10-mW/cm(2) irradiance. Animals were killed and both treated and control corneas were then immediately mounted on a corneal artificial anterior chamber and internal pressure was varied from 15 to 50 mm Hg in 5-mm Hg increments. Swelling was evaluated via central corneal thickness measurements. Ex vivo inflation tests were monitored using SSI technology that provides real-time mapping of the corneal elasticity.

RESULTS: Corneal yellowing of the central 9-mm diameter area was clearly visible in the iontophoresis area of all treated eyes. Elasticity versus internal pressure revealed significant differences of the change in elasticity coefficient with pressure between I-CXL-treated and control corneas with a mean slope that was 27.1 and 16.9 kPa/mm Hg, respectively (P = 0.029). Differences in elasticity at individual pressure levels between groups were statistically significant above 40 mm Hg (P < 0.05).

CONCLUSIONS: Intraocular pressure variations were the most important limitations for in vivo stiffness monitoring with SSI because stiffness is a function of internal pressure. Supersonic shear wave imaging succeeded in comparing corneas that underwent I-CXL by performing ex vivo inflation tests where pressure was controlled. Iontophoresis-assisted transepithelial corneal collagen cross-linking corneas exhibited increased resistance to pressure rise, indicating stiffening. In vivo I-CXL and ex vivo SSI is an interesting model to evaluate the sole effect of photopolymerization occurring in the CXL process close to physiological conditions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты