MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.13-13445

Медицинская библиотека · Investigative ophthalmology & visual science · 2014

Supersonic shear wave elastography for the in vivo evaluation of transepithelial corneal collagen cross-linking.

Touboul David, Gennisson Jean-Luc, Nguyen Thu-Mai, Robinet Antoine, Roberts Cynthia J, Tanter Mickael, Grenier Nicolas

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To assess corneal stiffening with supersonic shear wave imaging (SSI) technology in an experimental model of iontophoresis-assisted transepithelial corneal collagen cross-linking (I-CXL).

METHODS

Six rabbits underwent full, central I-CXL in one eye. The contralateral eye served as control. In vivo iontophoresis was used for 10 minutes to perform transepithelial delivery of riboflavin prior to UV-A irradiation. Accelerated UV-A protocol was applied for 9 minutes with a 10-mW/cm(2) irradiance. Animals were killed and both treated and control corneas were then immediately mounted on a corneal artificial anterior chamber and internal pressure was varied from 15 to 50 mm Hg in 5-mm Hg increments. Swelling was evaluated via central corneal thickness measurements. Ex vivo inflation tests were monitored using SSI technology that provides real-time mapping of the corneal elasticity.

RESULTS

Corneal yellowing of the central 9-mm diameter area was clearly visible in the iontophoresis area of all treated eyes. Elasticity versus internal pressure revealed significant differences of the change in elasticity coefficient with pressure between I-CXL-treated and control corneas with a mean slope that was 27.1 and 16.9 kPa/mm Hg, respectively (P = 0.029). Differences in elasticity at individual pressure levels between groups were statistically significant above 40 mm Hg (P < 0.05).

CONCLUSIONS

Intraocular pressure variations were the most important limitations for in vivo stiffness monitoring with SSI because stiffness is a function of internal pressure. Supersonic shear wave imaging succeeded in comparing corneas that underwent I-CXL by performing ex vivo inflation tests where pressure was controlled. Iontophoresis-assisted transepithelial corneal collagen cross-linking corneas exhibited increased resistance to pressure rise, indicating stiffening. In vivo I-CXL and ex vivo SSI is an interesting model to evaluate the sole effect of photopolymerization occurring in the CXL process close to physiological conditions.

Для цитирования: Touboul David, Gennisson Jean-Luc, Nguyen Thu-Mai, Robinet Antoine, Roberts Cynthia J, Tanter Mickael, Grenier Nicolas. Supersonic shear wave elastography for the in vivo evaluation of transepithelial corneal collagen cross-linking.. Investigative ophthalmology & visual science. 2014. DOI: 10.1167/iovs.13-13445.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.