MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000000048

Медицинская библиотека · Cornea · 2014

Estimation of the central corneal power in keratoconus: theoretical and clinical assessment of the error of the keratometric approach.

Piñero David P, Camps Vicent J, Caravaca-Arens Esteban, Pérez-Cambrodí Rafael J, Artola Alberto

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to analyze theoretically the errors in the central corneal power calculation in eyes with keratoconus when a keratometric index (nk) is used and to clinically confirm the errors induced by this approach.

METHODS

Differences (ΔPc) between central corneal power estimation with the classical nk (Pk) and with the Gaussian equation ((Equation is included in full-text article.)) in eyes with keratoconus were simulated and evaluated theoretically, considering the potential range of variation of the central radius of curvature of the anterior (r1c) and posterior (r2c) corneal surfaces. Further, these differences were also studied in a clinical sample including 44 keratoconic eyes (27 patients, age range: 14-73 years). The clinical agreement between Pk and (Equation is included in full-text article.)(true net power) obtained with a Scheimpflug photography-based topographer was evaluated in such eyes.

RESULTS

For nk = 1.3375, an overestimation was observed in most cases in the theoretical simulations, with ΔPc ranging from an underestimation of -0.1 diopters (D) (r1c = 7.9 mm and r2c = 8.2 mm) to an overestimation of 4.3 D (r1c = 4.7 mm and r2c = 3.1 mm). Clinically, Pk always overestimated the (Equation is included in full-text article.)given by the topography system in a range between 0.5 and 2.5 D (P < 0.01). The mean clinical ΔPc was 1.48 D, with limits of agreement of 0.71 and 2.25 D. A very strong statistically significant correlation was found between ΔPc and r2c (r = -0.93, P < 0.01).

CONCLUSIONS

The use of a single value for nk for the calculation of corneal power is imprecise in keratoconus and can lead to significant clinical errors.

Для цитирования: Piñero David P, Camps Vicent J, Caravaca-Arens Esteban, Pérez-Cambrodí Rafael J, Artola Alberto. Estimation of the central corneal power in keratoconus: theoretical and clinical assessment of the error of the keratometric approach.. Cornea. 2014. DOI: 10.1097/ico.0000000000000048.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.