AIMS: To investigate the visual and refractive outcomes, safety, efficacy and stability of cataract surgery in eyes with stable keratoconus.

METHODS

17 eyes (10 patients) diagnosed as stable keratoconus, aged from 34 to 73 years (56.63 ± 12.47), underwent micro-incision cataract surgery (MICS) followed by implantation of toric intraocular lens (IOL). Seven of them were operated bilaterally and three unilaterally. A complete ophthalmological examination was performed preoperatively and postoperatively. The main outcome measures were: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry and manifest refraction.

RESULTS

Sphere changed from -1.77 ± 6.57D (-11.00 to 7.00) preoperatively to 0.08 ± 0.79D (-1.25 to 1.75) postoperatively (p=0.211), and cylinder changed from -2.95 ± 1.71D (-7.00 to -0.75) to -1.40 ± 1.13D (-3.25 to 0.00) (p=0.016). UDVA (logMAR) changed from 1.33 ± 0.95 (0.40 to 2.77) to 0.32 ± 0.38 (0.00 to 1.30) (p=0.008) and CDVA (logMAR) changed from 0.32 ± 0.45 (0.01 to 1.77) to 0.20 ± 0.36 (-0.03 to 1.30) (p=0.013). Efficacy and safety indexes were 1.38 ± 0.58 and 1.17 ± 0.66, respectively. Refraction and corneal topography were stable during the follow-up (9.10 ± 5.54 months, 3-15)

CONCLUSIONS

MICS surgery using corneal topography data and standard formulas for the calculation of the IOL power is a safe and effective procedure regarding keratometric stability, visual and refractive results.

Для цитирования: Alió Jorge L, Peña-García Pablo, Abdulla Guliyeva Fidan, Soria Felipe A, Zein Ghassam, Abu-Mustafa Sabat K. MICS with toric intraocular lenses in keratoconus: outcomes and predictability analysis of postoperative refraction.. The British journal of ophthalmology. 2014. DOI: 10.1136/bjophthalmol-2013-303765.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.