Asia-Pacific journal of ophthalmology (Philadelphia, Pa.) · 2014
Single-Segment Intacs Severe Keratoconus 80% Stromal Depth Insertion With a Femtosecond Laser for Asymmetric Keratoconus: A Case Series.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sánchez-Thorin Juan Camilo, Navarro Pedro-Ivan
Аннотация
PURPOSE: To study the efficacy of inferior, single-segment, 80% stromal depth Intacs severe keratoconus (SK) intracorneal ring segment implantation.
DESIGN: A prospective case series.
METHODS: Eighteen eyes from 15 patients with asymmetric keratoconus underwent 80% stromal depth Intacs SK single inferior segment implantation, using an IntraLase femtosecond laser for tunnel creation. Parameters studied included preoperative and postoperative uncorrected and best-corrected visual acuity (VA), manifest refraction and elevation-based computerized corneal topography.
RESULTS: Patients' VA was tested with Early Treatment Diabetic Retinopathy Study (ETDRS) chart. All the eyes demonstrated a significant ETDRS line improvement of 5.4 ± 2.0 after a follow-up period of 8.9 ± 3.9 months. Thirteen eyes (72%) showed a line improvement of 4 or more. Best-corrected VA remained unchanged in 8 eyes (44%) while 7 eyes (39%) showed a line improvement of 1 to 8. Sixteen eyes (89%) had a significant change in manifest cylinder [3.0 ± 2.2 diopters (D)]. Of the 18 eyes, astigmatism reduction was 3.44 ± 1.98 D, from 5.6 ± 2.2 D preoperatively to 2.5 ± 1.5 D postoperatively (P < 0.05). Implant placement reduced both preexisting hyperopic and myopic spheres in 14 cases (78%). Although one case showed a significant postoperative regression of the obtained correction, Intacs SK implantation was safe and effective in all the other cases.
CONCLUSIONS: Femtosecond laser-assisted single-segment Intacs SK (80% depth intrastromal placement) is a safe and effective technique for improving uncorrected and best-corrected VA and correcting both spherical and cylindrical refractive errors in eyes with severe asymmetric keratoconus.
DESIGN: A prospective case series.
METHODS: Eighteen eyes from 15 patients with asymmetric keratoconus underwent 80% stromal depth Intacs SK single inferior segment implantation, using an IntraLase femtosecond laser for tunnel creation. Parameters studied included preoperative and postoperative uncorrected and best-corrected visual acuity (VA), manifest refraction and elevation-based computerized corneal topography.
RESULTS: Patients' VA was tested with Early Treatment Diabetic Retinopathy Study (ETDRS) chart. All the eyes demonstrated a significant ETDRS line improvement of 5.4 ± 2.0 after a follow-up period of 8.9 ± 3.9 months. Thirteen eyes (72%) showed a line improvement of 4 or more. Best-corrected VA remained unchanged in 8 eyes (44%) while 7 eyes (39%) showed a line improvement of 1 to 8. Sixteen eyes (89%) had a significant change in manifest cylinder [3.0 ± 2.2 diopters (D)]. Of the 18 eyes, astigmatism reduction was 3.44 ± 1.98 D, from 5.6 ± 2.2 D preoperatively to 2.5 ± 1.5 D postoperatively (P < 0.05). Implant placement reduced both preexisting hyperopic and myopic spheres in 14 cases (78%). Although one case showed a significant postoperative regression of the obtained correction, Intacs SK implantation was safe and effective in all the other cases.
CONCLUSIONS: Femtosecond laser-assisted single-segment Intacs SK (80% depth intrastromal placement) is a safe and effective technique for improving uncorrected and best-corrected VA and correcting both spherical and cylindrical refractive errors in eyes with severe asymmetric keratoconus.