m+Medelevator.RU
← Поиск публикаций
Investigative ophthalmology & visual science · 2007

The effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy in glaucoma.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Medeiros Felipe A, Ng Diana, Zangwill Linda M, Sample Pamela A, Bowd Christopher, Weinreb Robert N

Аннотация

PURPOSE: To assess the effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy (CSLO) in glaucoma.

METHODS: Analysis 1 included 67 eyes with glaucomatous visual field loss and 56 eyes of normal volunteers. Estimates of diagnostic accuracy in this analysis were compared to those obtained from analysis 2, which included a cohort of patients with suspected glaucoma, but without visual field loss at the time of CSLO imaging. For analysis 2, 40 eyes with progressive glaucomatous optic disc change were included in the glaucoma group and 43 eyes without any evidence of progressive damage to the optic nerve that were observed untreated for an average time of 9.01 +/- 3.09 years were included in the normal group. Areas under the receiver operating characteristic (ROC) curves (AUC) were used to evaluate diagnostic accuracy of CSLO parameters.

RESULTS: There was a statistically significant difference between the performance of the parameter with largest AUC, discriminant function Bathija, in analysis 1 (AUC = 0.91) compared with its performance in analysis 2 (AUC = 0.71; P = 0.002). For the contour-line-independent parameter glaucoma probability score, a statistically significant difference was also observed in the performance obtained in analysis 1 (AUC = 0.89) compared with analysis 2 (AUC = 0.65; P < 0.001).

CONCLUSIONS: Estimates of diagnostic accuracy of CSLO in glaucoma can be largely different depending on the population studied and the reference standard used to define disease. Diagnostic accuracy estimates obtained from case-control studies including well-defined groups of subjects with or without disease may not be applicable to the clinically relevant population.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты