[Intacsintracorneal ring segments in keratoconus].

Клиническое исследованиеАннотация на английскомСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

El-Husseiny M, Tsintarakis T, Eppig T, Langenbucher A, Seitz B

Аннотация

INTRODUCTION: The spectrum of stage-related therapy of keratoconus has been broadened through surgical implantation of intracorneal ring segments (INTACS) as a possible method of reducing irregular astigmatism, leading to a reduction of corneal grafts especially in young, working-aged patients with keratoconus. The purpose of the present study was to evaluate the preoperative and postoperative results of femtosecond laser-assisted implantation of INTACS in ectatic corneal diseases.

PATIENTS AND METHODS: From August 2011 to January 2013, 20 eyes from 16 patients with a clear cornea in the visual axis suffering from hard contact lens intolerance underwent surgery in the Homburg/Saar Keratoconus Center (HKC) by the same surgeon (MEH). Among these were 16 keratoconus eyes, 1 eye with pellucid marginal degeneration und 3 eyes with post-LASIK iatrogenic keratectasia. The insertion of the INTACS ring segments was achieved by a femtosecond laser-assisted procedure that created a precise 360° tunnel at a depth of 80% of the corneal thickness (395.8 ± 38.5 μm) in the 6–7 mm zone.Results. At 6 months follow-up mean uncorrected distance visual acuity improved from 0.07 ± 0.07 preoperatively to 0.6 ± 0.26 postoperatively. Mean best-corrected distance visual acuity changed from 0.4 ± 0.15 preoperatively to 0.9 ± 0.29 postoperatively. Mean sphere decreased from −7.6 ± 6.1 dpt to −1.4 ± 2.8 dpt. Astigmatism decreased from −6.0 ± 2.8 dpt preoperatively to −4.3 ± 2.0 dpt postoperatively. There was also a reduction in the mean flat K from 47.8 ± 4.7 dpt preoperatively to 44.2 ± 5.0 dpt postoperatively and in mean steep K from 51.9 ± 5.0 dpt to 48.4 ± 6.6 dpt. The central eccentricity index in the Pentacam was reduced to around 50%. Neither intraoperative nor postoperative complications (including non-responders) were observed.

CONCLUSIONS: The femtosecond laser-assisted INTACS implantation provides a valid alternative to early keratoplasty for keratoconus patients with a clear central cornea and contact lens intolerance. It is a minimally invasive and reliable method for stage-related surgical management of keratoconus.