MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-013-2458-5

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2013

Visual outcomes of Femto-LASIK for correction of residual refractive error after corneal graft.

Ghoreishi Mohammad, Naderi Beni Afsaneh, Naderi Beni Zahra

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the outcomes of the Femto-LASIK method in the treatment of refractive errors following penetrating keratoplasty (PK) at the Persian Eye Clinic, Isfahan, Iran

METHODS

In a prospective, non-comparative case series, 34 consecutive symptomatic eyes of 34 patients after corneal graft, were operated on. Tissue-saving (TS) Femto-LASIK (n = 16), and Zyoptix Personalized Treatment Advanced (PTA) Femto-LASIK (n = 18) were performed using the Bausch & Lomb Technolas 217z excimer laser and Zyoptic algorithm. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), manifest refraction, contrast sensitivity, and HOAs were evaluated preoperatively and 12 months after enhancement treatment.

RESULTS

At 12 months, the mean preoperative myopic spherical equivalent refraction (SE) decreased from -6.50 ± 2.8 D to -1.6 ± 1.8 D, and mean hyperopic SE from +3.2 ± 2.20 D to 0.37 ± 1.2 D. The safety index was 1.42 (1.2 in the TS group and 1.5 in the PTA group). In the TS group, 100% of eyes achieved 20/80 or better UCVA and 50%, 20/40 or better and in the PTA group, 100% of eyes achieved 20/80 or better UCVA and 77.7%, 20/40 or better. The efficacy index was 1.08 (0.9 in TS group and 1.21 in the PTA group). Patients obtained statistically significant lower values of root mean square (RMS) of HOAs with spherical aberrations (p < 0.05).

CONCLUSIONS

Femto-LASIK method with Zyoptic programs after PK was safe, effective, and predictable for correction of spherical and cylindrical components of the refractive error.

Для цитирования: Ghoreishi Mohammad, Naderi Beni Afsaneh, Naderi Beni Zahra. Visual outcomes of Femto-LASIK for correction of residual refractive error after corneal graft.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2013. DOI: 10.1007/s00417-013-2458-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.