Evaluation of the VITEK 2 second-generation cassette for colistin susceptibility testing in carbapenem-resistant gram-negative bacteria.

Günaydın Betül, Kutlu Hüseyin Haydar, Kurç Mine Aydın

СтатьяОценочное исследованиеПеревод пока не подготовлен

Аннотация

The global rise in antimicrobial resistance has increased morbidity and mortality, particularly among patients with multidrug-resistant Gram-negative infections. Colistin, a last-resort therapeutic, has faced a concerning emergence of resistance. Accurate detection is therefore critical in clinical microbiology laboratories. Although broth microdilution (BMD) is the only reference method recommended for colistin susceptibility testing, its labor-intensive process has driven the search for automated alternatives. The VITEK 2 system is widely used in routine diagnostics, but international guidelines do not recommend automated platforms for colistin testing. A second-generation colistin susceptibility cassette (XN-21) was recently developed to address these limitations. This study evaluated the performance of the VITEK 2 XN-21 cassette against BMD. Identification and susceptibility testing were performed using VITEK 2 GN and AST-420 cards. Colistin susceptibility was assessed by both BMD and XN-21. Isolates classified as susceptible by BMD but resistant by VITEK 2 underwent population analysis profiling (PAP) to investigate heteroresistance. Results were interpreted according to ISO 20776-2 standards. Colistin resistance was detected in 59 % of isolates by BMD and 52 % by XN-21. The sensitivity and specificity of XN-21 were 81.3 % and 90.2 %, respectively. Essential and categorical agreement with BMD were 73 % and 85 %. Very major error and major error rates were 11 % and 4 %. Among 11 very major errors, nine were Klebsiella pneumoniae; PAP confirmed heteroresistance in three of four major error isolates. The VITEK 2 XN-21 cassette offers convenience but does not yet meet reference standards. Its potential in detecting heteroresistant subpopulations merits further evaluation.

Для цитирования: Günaydın Betül, Kutlu Hüseyin Haydar, Kurç Mine Aydın. Evaluation of the VITEK 2 second-generation cassette for colistin susceptibility testing in carbapenem-resistant gram-negative bacteria.. Diagnostic microbiology and infectious disease. 2025. DOI: 10.1016/j.diagmicrobio.2025.117148.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.