MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mri.2025.110416

Медицинская библиотека · Magnetic resonance imaging · 2025

Appropriate strength of acceleration selective-motion sensitized gradient for non-triggered, non-contrast enhanced magnetic resonance angiography of the lower extremities.

Konta Natsuo, Hayashi Norio, Shibukawa Shuhei, Horie Tomohiko, Niwa Tetsu, Obara Makoto, Kawamura Yui, Miyati Toshiaki

СтатьяПеревод пока не подготовлен

Аннотация

Non-contrast enhanced magnetic resonance angiography (MRA) is useful for diagnosing peripheral arterial disease, especially in patients with renal insufficiency. Recently, non-triggered, non-contrast enhanced MRA using acceleration selective-motion sensitized gradient (AS-MSG), known as enhanced acceleration-selective arterial spin labeling (eAccASL), has been introduced. We aimed to investigate the appropriate strength of the AS-MSG for this technique in the lower extremities. Non-triggered eAccASL with four acceleration encodings (AENCs; 0.17, 0.29, 0.58, and 0.87 m/s2) was compared with electrocardiography (ECG)-triggered eAccASL (AENC: 0.87 m/s2). In the flow phantom, signal intensities (SIs) were calculated. A higher SI was observed with a smaller AENC on non-triggered eAccASL. In eight volunteers, vessel-background contrasts (VBCs) were calculated, and arterial visibility and venous artifacts were assessed by two radiologists. A higher VBC was observed with a smaller AENC on non-triggered eAccASL. The VBCs of non-triggered eAccASL 0.87 were lower than those of ECG-triggered eAccASL 0.87 in the peroneal, and anterior and posterior tibial arteries (all p < 0.05). Subjective scores for arterial visibility did not differ, with median scores within acceptable levels. The venous artifacts score of non-triggered eAccASL 0.17 was lower than those of non-triggered eAccASL 0.29, 0.58, and 0.87 and ECG-triggered eAccASL 0.87 (p < 0.01, p < 0.05, p < 0.001, and p < 0.01, respectively). In two clinical patients, arterial visibility on non-triggered eAccASL 0.29 was comparable or superior to that on ECG-triggered eAccASL 0.87. An AENC of 0.29-0.58 m/s2 was considered appropriate for non-triggered, non-contrast enhanced lower-extremity MRA using eAccASL.

Для цитирования: Konta Natsuo, Hayashi Norio, Shibukawa Shuhei, Horie Tomohiko, Niwa Tetsu, Obara Makoto, Kawamura Yui, Miyati Toshiaki. Appropriate strength of acceleration selective-motion sensitized gradient for non-triggered, non-contrast enhanced magnetic resonance angiography of the lower extremities.. Magnetic resonance imaging. 2025. DOI: 10.1016/j.mri.2025.110416.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.