MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/08465371251356908

Медицинская библиотека · Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes · 2025

Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study.

Rogers Patrick, Parker Ellen, Marangoni Marco, MacDonald Ian R, Kim Cha-Ney, Hendriks Eef J, Volders David

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: Accurate vessel measurement is essential in endovascular thrombectomy (EVT) for acute ischemic stroke. Discrepancies between computed tomography angiography (CTA) and digital subtraction angiography (DSA) may impact procedural planning and device selection. This study compares vessel diameter measurements from CTA and DSA in patients with middle cerebral artery (MCA) M1 occlusions.

METHODS

In this single-center retrospective study, 90 consecutive patients who underwent EVT for MCA M1 occlusions between February 2020 and March 2024 were included. Vessel diameters were independently measured by 3 neuroradiologists using CTA and DSA (pre- and post-intervention). Statistical analysis included Wilcoxon signed-rank tests, intraclass correlation coefficient (ICC), and Bland-Altman analysis.

RESULTS

CTA consistently overestimated vessel diameter compared to DSA. The mean M1 diameter was 2.29 ± 0.27 mm on CTA and 2.16 ± 0.30 mm on pre-EVT DSA (P < .001), with a median difference of 0.4 mm (IQR: 0.2-0.6 mm). In 70% of cases, CTA values exceeded DSA. Bland-Altman analysis confirmed a mean difference of +0.13 mm (limits of agreement: -0.25 to +0.51 mm). No significant change was observed between pre- and post-EVT DSA measurements (P = .103). Clot-side M1 segments were significantly smaller than contralateral measurements on CTA (P = .003). Inter-rater agreement was good (ICC = .785).

CONCLUSIONS

CTA overestimates MCA M1 diameter relative to DSA. While the discrepancy is modest, it may influence device selection in borderline cases. Awareness of this variability is important, and further research is warranted to explore its clinical implications.

Для цитирования: Rogers Patrick, Parker Ellen, Marangoni Marco, MacDonald Ian R, Kim Cha-Ney, Hendriks Eef J, Volders David. Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study.. Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes. 2025. DOI: 10.1177/08465371251356908.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.