MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2024.111427

Медицинская библиотека · European journal of radiology · 2024

Interoperator reproducibility of quantitative ultrasound analysis of hepatic steatosis in participants with suspected MASLD: A prospective study.

Yin Haohao, Xiong Bing, Yu Jifeng, Fan Yunling, Zhou Boyang, Sun Yikang, Wang Lifan, Xu Huixiong, Zhu Yuli

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the reproducibility of tissue attenuation imaging (TAI) and tissue scatter distribution imaging (TSI) measurements in adults with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) between radiologists with varying experience.

MATERIALS AND

METHODS

Participants with suspected MASLD were prospectively recruited. TAI and TSI were performed for each participant by two radiologists with different levels of experience. Interoperability reliability was assessed on the basis of Bland-Altman analysis and intraclass correlation coefficients (ICCs). The study determined and compared the diagnostic performance of TAI and TSI with clinical prediction models using proton magnetic resonance spectroscopy (1H-MRS) as a reference.

RESULTS

A total of 180 participants (women, n = 56; men, n = 124, mean age, 46.98 ± 14.92 years; mean BMI, 25.81 ± 4.47) were enrolled from August 2022 to September 2022. Bland-Altman plots showed only slight deviation in the TAI and TSI results of the two radiologists; there was good interoperator reproducibility for TAI (ICC = 0.92) and TSI (ICC = 0.86). Senior and junior radiologists performed examinations labeled as TAI-1 and TSI-1, and TAI-2 and TSI-2, respectively. The areas under the curves (AUCs) of TAI-1, TAI-2, TSI-1, and TAI-2 for the detection of ≥5 % hepatic steatosis were 0.90, 0.96, 0.91 and 0.96, respectively. According to ROC analysis, the diagnostic performance of both radiologists for TAI and TSI was statistically similar and superior to that of the clinical prediction model.

CONCLUSIONS

TAI and TSI have good reproducibility between radiologists with different levels of experience. Meanwhile, both TAI and TSI demonstrated good diagnostic performance for hepatic steatosis (≥5%), surpassing that of clinical prediction models.

Для цитирования: Yin Haohao, Xiong Bing, Yu Jifeng, Fan Yunling, Zhou Boyang, Sun Yikang, Wang Lifan, Xu Huixiong, Zhu Yuli. Interoperator reproducibility of quantitative ultrasound analysis of hepatic steatosis in participants with suspected MASLD: A prospective study.. European journal of radiology. 2024. DOI: 10.1016/j.ejrad.2024.111427.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.