Usefulness of second-generation motion correction algorithm in improving delineation and reducing motion artifact of coronary computed tomography angiography.

Yamaguchi Shintaro, Ichikawa Yasutaka, Takafuji Masafumi, Sakuma Hajime, Kitagawa Kakuya

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The purpose of this study was to investigate the usefulness of second-generation intra-cycle motion correction algorithm (SnapShot Freeze 2, GE Healthcare, MC2) in improving the delineation and interpretability of coronary arteries in coronary computed tomography angiography (CCTA) compared to first-generation intra-cycle motion correction algorithm (SnapShot Freeze, GE Healthcare, MC1).

METHODS

Fifty consecutive patients with known or suspected coronary artery disease who underwent CCTA on a 256-slice CT scanner were retrospectively studied. CCTA were reconstructed with three different algorithms: no motion correction (NMC), MC1, and MC2. The delineation of coronary arteries on CCTA was qualitatively rated on a 5-point scale from 1 (nondiagnostic) to 5 (excellent) by two radiologists blinded to the reconstruction method and the patient information.

RESULTS

On a per-vessel basis, the delineation scores of coronary arteries were significantly higher on MC2 images compared to MC1 images (median [interquartile range], right coronary artery, 5.0 [4.5-5.0] vs 4.5 [4.0-5.0]; left anterior descending artery, 5.0 [4.5-5.0] vs 4.5 [3.5-5.0]; left circumflex artery, 5.0 [4.5-5.0] vs 4.5 [3.9-5.0]; all p ​< ​0.05). On a per-segment basis, for both 2 observers, the delineation scores on segment 1, 2, 8, 9, 10, 12 and 13 on MC2 images were significantly better than those on MC1 images (p ​< ​0.05). The percentage of interpretable segments (rated score 3 or greater) on NMC, MC1, and MC2 images was 90.5-91.9%, 97.4-97.9%, and 100.0%, respectively.

CONCLUSION

Second-generation intra-cycle motion correction algorithm improves the delineation and interpretability of coronary arteries in CCTA compared to first-generation algorithm.

Для цитирования: Yamaguchi Shintaro, Ichikawa Yasutaka, Takafuji Masafumi, Sakuma Hajime, Kitagawa Kakuya. Usefulness of second-generation motion correction algorithm in improving delineation and reducing motion artifact of coronary computed tomography angiography.. Journal of cardiovascular computed tomography. 2024. DOI: 10.1016/j.jcct.2024.02.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.