m+Medelevator.RU
← Поиск публикаций
Vascular · 2020

Drug-coated balloon angioplasty for the treatment of edge stenosis after self-expanding covered stent placement for superficial femoral artery occlusive disease.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

van Wijck Iris Ps, Holewijn Suzanne, van Walraven Laurens A, Reijnen Michel Mpj

Аннотация

BACKGROUND: Edge stenoses are the predominant limitation of self-expanding covered stent treatment of superficial femoral artery (SFA) occlusive disease, necessitating reinterventions. Angioplasty of an edge stenosis is associated with a high recurrence rate. Drug-coated balloon (DCB) treatment of edge stenoses might improve outcomes by decreasing the incidence of restenosis.

PURPOSE: The aim of this study was to evaluate the outcomes of using a DCB for the treatment of edge stenoses after self-expanding covered stent placement for SFA occlusive disease.

METHOD: We performed a retrospective analysis of patients treated with a DCB for edge stenoses after self-expanding covered stent placement. The primary endpoint was primary patency at one year. The secondary endpoints included procedure-related complications, secondary patency, and freedom from target lesion revascularization (TLR).

RESULTS: A total of 21 patients with 28 edge stenoses were included. The time from primary treatment to treatment of the edge stenosis was 19 months (interquartile range (IQR) 8; 52 months). Primary patency and assisted primary patency at one year were 66.7% with a secondary patency of 90.9%. Freedom from TLR was 86.1%, and freedom from clinically driven TLR was 89.4%. Four patients presented with a hemodynamically significant restenosis, and three of those patients had an occlusion. Median time to failure was six months (IQR 3.5; 7.0 months), and median time to occlusion was four months (IQR 3.0; 6.0 months).

CONCLUSION: The treatment of edge stenoses using a DCB is associated with a safe one-year outcome; however, this has to be confirmed in larger prospective studies. The continuous surveillance of patients is indicated.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты