MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/pho.2024.0057

Медицинская библиотека · Photobiomodulation, photomedicine, and laser surgery · 2024

Comparative Effectiveness of Different Er:YAG Laser-Activated Irrigation Systems on Removing Calcium Hydroxide from Simulated Internal Root Resorption Cavities at Different Root Levels.

Myint Phu Yadanar Aung, Watanabe Satoshi, Okiji Takashi

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

Objective

To investigate the effectiveness of Er:YAG laser-activated irrigation (LAI) with a short pulse duration for removing calcium hydroxide (CH) from simulated internal root resorption (IRR) cavities at three root levels.

Background

Pulse duration is an important parameter during LAI, which ensures the efficiency of irradiation and the corresponding activation process. Short pulses in the range of a few microseconds enable rapid expansion and successive implosion of irrigants, resulting in distinct fluid movement. There have been few reports on CH removal efficacy from IRR cavities of different LAI systems, including those using short pulse duration.

Methods

IRR cavities (1.6 mm diameter) were created at the apical, middle, and coronal root levels in 60 mandibular premolars and filled with a radiopaque CH paste. Samples were assigned to the following irrigation groups (n = 12, each): (1) LAI(P)-F, a prototype laser device that operates with short pulse duration (Morita Manufacturing) with a flat tip; (2) LAI(EA)-F, the ErwinAdverl laser device (Morita Manufacturing) with a flat tip; (3) LAI(EA)-T, the ErwinAdverl laser device with a tapered tip; (4) PIPS-T, the Lightwalker laser device (Fotona) with a tapered tip; and (5) SI, the syringe irrigation group. The laser tips were fixed at the canal entrance. The remaining CH volume and surface area were assessed in IRR cavities using micro-computed tomography and scanning electron microscopy, respectively. Data were statistically analyzed utilizing one-way analysis of variance and Tukey's test at 5% significance level.

Results

The LAI(P)-F and PIPS-T groups exhibited the highest CH removal rates at three different levels (p < 0.05). The LAI(EA)-F group had a significantly better efficacy of CH removal compared with the LAI(EA)-T group at the middle level (p < 0.05).

Conclusion

The LAI(P)-F and PIPS-T groups demonstrated superior efficiency in removing CH from simulated IRR cavities.

Для цитирования: Myint Phu Yadanar Aung, Watanabe Satoshi, Okiji Takashi. Comparative Effectiveness of Different Er:YAG Laser-Activated Irrigation Systems on Removing Calcium Hydroxide from Simulated Internal Root Resorption Cavities at Different Root Levels.. Photobiomodulation, photomedicine, and laser surgery. 2024. DOI: 10.1089/pho.2024.0057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.