MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/ajvr.25.04.0111

Медицинская библиотека · American journal of veterinary research · 2025

A body weight-based formula of the canine aortic valve diameter for use in echocardiographic stroke volume and cardiac output calculations.

Kennedy Christopher R, Gommeren Kris, Duriez Laurentin, Merveille Anne-Christine

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To generate and test a formula to predict the echocardiographic aortic valve (AV) diameter (AVd) for use in echo-hemodynamic evaluations.

METHODS

Echocardiograms of hemodynamically stable dogs more than 1 year old that included images of the AV in the right parasternal inflow-outflow view with concurrent ECG were included. Exclusions included AV pathology, congestive heart failure, systolic dysfunction, sustained arrhythmias, congenital heart diseases, hypovolemia, systemic hypertension, and pericardial and pleural space diseases. The AVd was measured in centimeters in triplicate using digital calipers. A linear regression examined the relationship between weight and AVd, generating a predictive formula. Next, 20 dogs had their AVd measured and predicted, and stroke volumes were calculated using each method. These were compared using the paired Student t test, intraclass correlation coefficients, coefficients of variation, and Bland-Altman plots.

RESULTS

Data from 176 unique dogs included 64 (34.7%) normal hearts and 109 (61.9%) with preclinical myxomatous mitral and/or tricuspid valve disease. The median (range) age was 8 (1 to 16) years; weight was 9.6 (1.7 to 73) kg. The median (range) AVd was 1.20 (0.60 to 2.45) cm. The formula derived was AVd = 0.545 X (weight)0.347 (r2 = 0.875). Despite moderate agreement and low variation between the predicted and measured AVd, differences occurred due to mild systematic underestimation (-0.1 ± 0.13 cm), with consequent underestimation of stroke volumes.

CONCLUSIONS

The formula allowed calculation of AVd, although underestimation resulted in differences between measured and predicted stroke volumes.

CLINICAL RELEVANCE: Using a formula can reduce acquisition and measurement error; however, it must be validated with a larger sample.

Для цитирования: Kennedy Christopher R, Gommeren Kris, Duriez Laurentin, Merveille Anne-Christine. A body weight-based formula of the canine aortic valve diameter for use in echocardiographic stroke volume and cardiac output calculations.. American journal of veterinary research. 2025. DOI: 10.2460/ajvr.25.04.0111.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.