m+Medelevator.RU
← Поиск публикаций
JTCVS techniques · 2026

Konno aortic valve replacement in adults: Enabling larger prosthetic valve implantation and adequate aortic root enlargement for coronary clearance.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yoshioka Daisuke, Kawamura Ai, Shimamura Kazuo, Kawamura Takuji, Yajima Shin, Misumi Yusuke, Saito Shunsuke, Miyagawa Shigeru

Аннотация

OBJECTIVE: Surgical aortic valve replacement in patients with severe aortic stenosis and small annuli remains challenging owing to prosthesis-patient mismatch and the limited feasibility of subsequent valve-in-valve transcatheter aortic valve replacement (ViV-TAVR). The Konno procedure enables annular and left ventricular outflow tract (LVOT) enlargement; however, outcomes in adults remain insufficiently defined.

METHODS: Between January 2023 and October 2025, 193 patients underwent surgical aortic valve replacement at our institution, of whom 19 (10%) received the Konno procedure for annulus diameter ≤19 mm, high likelihood of prosthesis-patient mismatch, or anticipated ViV-TAVR with estimated high risk of coronary obstruction. Operative results, echocardiographic and electrocardiographic parameters, and computed tomography measurements of the aortic root were assessed before and after surgery.

RESULTS: Patients were aged 59 ± 19 years and 84% were women. Bioprostheses were implanted in 12 patients (63%) and mechanical valves in seven (37%), with enlargement permitting prosthesis implantation 2 to 3 sizes larger. Septal myectomy was performed in 6 patients. No in-hospital mortality occurred. Computed tomography demonstrated enlargement of the sinus of Valsalva (+7.0 mm) and sinotubular junction (+6.9 mm), consistent with ViV-TAVR feasibility. Echocardiography confirmed relief of LVOT obstruction; however, right ventricular diameter tended to increase, tricuspid annular plane systolic excursion declined, and QRS duration increased from 90 to 114 milliseconds, indicating intraventricular conduction delay.

CONCLUSIONS: Konno aortic valve replacement facilitates implantation of larger prostheses, relieves LVOT obstruction, and optimizes root anatomy for future ViV-TAVR. Conduction disturbances and right ventricular functional decline warrant long-term surveillance.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты