Efficacy of corneal curvature on the accuracy of 8 intraocular lens power calculation formulas in 302 highly myopic eyes.

Mo Er, Feng Ke, Li Qiyuan, Xu Jingyuan, Cen Jiaying, Li Jin, Zhao Yun-E

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the effect of corneal curvature (K) on the accuracy of 8 intraocular lens formulas in highly myopic eyes.

SETTING

Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.

DESIGN

Retrospective consecutive case series.

METHODS

302 eyes (302 patients) were analyzed in subgroups based on the K value. The mean refractive error, mean absolute error (MAE), median absolute error (MedAE), root-mean-square absolute prediction error (RMSAE) and proportions of eyes within ±0.25 diopter (D), ±0.50 D, ±0.75 D, ±1.00 D were statistical analyzed.

RESULTS

Emmetropia Verifying Optical (EVO) 2.0, Kane, and Radial Basis Function (RBF) 3.0 had the lower MAE (≤0.28) and RMSAE (≤0.348) and highest percentage of eyes within ±0.50 D (≥83.58%) in the flat (K ≤ 43 D) and steep K (K > 45 D) groups. Hoffer QST had the lowest MedAE (0.19), RMSAE (0.351) and the highest percentage of eyes within ±0.50 D (82.98%) in the normal K group (43 < K ≤ 45 D). When axial length (AL) ≤28 mm, all formulas showed close RMSAE values (0.322 to 0.373) in flat K group. When AL >28 mm, RBF 3.0 achieved the lowest MAE (≤0.24), MedAE (≤0.17) and RMSAE (≤0.337) across all subgroups.

CONCLUSIONS

EVO 2.0, Kane, and RBF 3.0 were the most accurate in highly myopic eyes with a flat or steep K. Hoffer QST is recommended for long eyes with normal K values. RBF 3.0 showed the highest accuracy when AL >28 mm, independent of corneal curvature.

Для цитирования: Mo Er, Feng Ke, Li Qiyuan, Xu Jingyuan, Cen Jiaying, Li Jin, Zhao Yun-E. Efficacy of corneal curvature on the accuracy of 8 intraocular lens power calculation formulas in 302 highly myopic eyes.. Journal of cataract and refractive surgery. 2023. DOI: 10.1097/j.jcrs.0000000000001303.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.