BMC ophthalmology · 2023
A vault-prediction formula for implantable collamer lens based on preoperative parameters: a retrospective clinical study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yang Jing, Li Hui, Wu Minhui, He Runzhang, Nong Yating, Zou Zongyin, Zhang Chun, Zhou Sheng
Аннотация
OBJECTIVES: The aim of the present study was to predict the vault of implantable collamer lens (ICL) using a formula established based on the preoperative parameters.
METHODS: This retrospective study included data on 226 eyes from 114 patients(the median age and range was 27.5 ± 5.7; 18-46 years) who underwent EVO-ICL surgery between May 2021 and April 2022. Preoperative parameters, such as anterior chamber depth (ACD) horizontal angle-to-angle diameter (ATA), Crystalline lens rise (CLR), and vault (1 week after surgery) were measured by anterior segment optical coherence tomography. The axial length of eyes (AL) and white-to-white (WTW) values were measured using an IOLmaster and calipers under a slit lamp separately.
RESULT: The mean WTW, ACD, horizontal ATA diameter, CLR, AL, and vault 1 week after surgery were 11.42 ± 0.37 mm, 3.25 ± 0.25 mm, 11.72 ± 0.44 mm, 45.78 ± 175.42 μm, 27.61 ± 1.93 mm, and 586.51 ± 254.54 μm respectively. Multivariate regression analysis showed that the ICL-width, ACD (β = 0.293), ATA (β =-0.657), CLR (β =-0.157), and the anterior chamber angle in temporal side (T:ACA) (β=-0.277) were predictors of the vault size (adjusted-R2 = 0.39, P < 0.001).
CONCLUSION: The formula built based on these preoperative parameters could be used to predict the vault before surgery. The predictors indicated that the pre-operative parameters of eye such as ACD, ATA, CLR and T:ACA play an important role in choosing optimal ICL size.
METHODS: This retrospective study included data on 226 eyes from 114 patients(the median age and range was 27.5 ± 5.7; 18-46 years) who underwent EVO-ICL surgery between May 2021 and April 2022. Preoperative parameters, such as anterior chamber depth (ACD) horizontal angle-to-angle diameter (ATA), Crystalline lens rise (CLR), and vault (1 week after surgery) were measured by anterior segment optical coherence tomography. The axial length of eyes (AL) and white-to-white (WTW) values were measured using an IOLmaster and calipers under a slit lamp separately.
RESULT: The mean WTW, ACD, horizontal ATA diameter, CLR, AL, and vault 1 week after surgery were 11.42 ± 0.37 mm, 3.25 ± 0.25 mm, 11.72 ± 0.44 mm, 45.78 ± 175.42 μm, 27.61 ± 1.93 mm, and 586.51 ± 254.54 μm respectively. Multivariate regression analysis showed that the ICL-width, ACD (β = 0.293), ATA (β =-0.657), CLR (β =-0.157), and the anterior chamber angle in temporal side (T:ACA) (β=-0.277) were predictors of the vault size (adjusted-R2 = 0.39, P < 0.001).
CONCLUSION: The formula built based on these preoperative parameters could be used to predict the vault before surgery. The predictors indicated that the pre-operative parameters of eye such as ACD, ATA, CLR and T:ACA play an important role in choosing optimal ICL size.