Robotic Anatrophic Nephrolithotomy Utilizing Near-infrared Fluorescence Image-guidance: Idea, Development, Exploration, Assessment, and Long-term Monitoring (IDEAL) Stage 0 Animal Model Study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sood Akshay, Hemal Ashok K, Assimos Dean G, Peabody James O, Menon Mani, Ghani Khurshid R

Аннотация

OBJECTIVE: To test the feasibility of robotic anatrophic nephrolithotomy (RANL) using near-infrared fluorescence (NIRF) image-guidance for treating staghorn stones, in an in vivo stone surgery model.

METHODS: We developed a novel technique of RANL in a preclinical setting following guidelines on safe surgical innovation from the Idea, Development, Exploration, Assessment, Long-term monitoring (IDEAL) collaborative. We performed 2 RANL procedures on 2 live Yorkshire porcine females (IDEAL stage 0 study). The robot was docked in the flank position and a mini-GelPOINT was placed periumbilically as an assistant port. A model staghorn "stone" was created in vivo by injecting low-viscosity DenMat precision material into the renal pelvis. NIRF image-guidance, following clamping of the posterior renal artery, was used to determine if an anatrophic plane could be identified. One procedure was assessed under cold ischemia, with ice-slush injected onto the renal surface via the mini-GelPOINT.

RESULTS: Both porcine subjects underwent RANL successfully. Replica staghorn models could be created reliably (mean size 5.1 cm; solidification time 2-3 minutes). NIRF image-guidance afforded clear vascular demarcation for precise scoring of an anatrophic plane in both kidneys. The staghorn models were removed in toto through the anatrophic incision in both subjects. Mean blood loss was 160 cc. Mean console and ischemia times were 114 minutes and 34.5 minutes, respectively; ice-slush hypothermia led to a renal surface temperature of 15.4°C.

CONCLUSION: In this IDEAL stage 0 preclinical study, we demonstrated that NIRF image-guidance is able to accurately identify the renal avascular plane, thus permitting an anatrophic approach for robotic excision of staghorn stones.