World neurosurgery · 2018
Novel Use of Pipeline Stent Device After Inadvertent Microcatheter Rupture During Arteriovenous Fistula Embolization.
Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cuellar Hugo, Maiti Tanmoy, Narayan Vinayak, Patra Deviprasad, Dossani Rimal, Sun Hai, Nanda Anil
Аннотация
BACKGROUND: Onyx, a liquid embolic agent, is the mainstay of embolization treatment of arteriovenous malformation or arteriovenous fistula. Microcatheter retention in an embolic cast is a well-known complication. Rupture of catheter with spillage of onyx is a rare phenomenon but can lead to potential occlusion of the parent vessel.
METHODS: We describe a case in which a patient with ruptured arteriovenous fistula experienced rupture of a microcatheter at the proximal part and spillage of onyx on embolization. A Pipeline embolization device (PED) was successfully deployed, and onyx was jailed between the catheter and vessel wall at the third segment of the vertebral artery (V3 segment). A balloon angioplasty helped to complete the opening of the stent.
RESULTS: The procedure was uneventful, and the patient recovered well. Follow-up angiogram revealed patency of posterior circulation. The 6-month follow-up angiogram revealed a patent stent.
CONCLUSIONS: Microcatheter rupture and spillage of onyx during embolization of arteriovenous malformation/arteriovenous fistula is a potential complication, and management should be individualized. The unique close cell design of the PED was successfully used to avoid a potentially life-threatening occlusion of the vertebrobasilar system. To the best of our knowledge, we report for the first time this novel use of PED.
METHODS: We describe a case in which a patient with ruptured arteriovenous fistula experienced rupture of a microcatheter at the proximal part and spillage of onyx on embolization. A Pipeline embolization device (PED) was successfully deployed, and onyx was jailed between the catheter and vessel wall at the third segment of the vertebral artery (V3 segment). A balloon angioplasty helped to complete the opening of the stent.
RESULTS: The procedure was uneventful, and the patient recovered well. Follow-up angiogram revealed patency of posterior circulation. The 6-month follow-up angiogram revealed a patent stent.
CONCLUSIONS: Microcatheter rupture and spillage of onyx during embolization of arteriovenous malformation/arteriovenous fistula is a potential complication, and management should be individualized. The unique close cell design of the PED was successfully used to avoid a potentially life-threatening occlusion of the vertebrobasilar system. To the best of our knowledge, we report for the first time this novel use of PED.