MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jsb.2015.06.014

Медицинская библиотека · Journal of structural biology · 2015

Description and comparison of algorithms for correcting anisotropic magnification in cryo-EM images.

Zhao Jianhua, Brubaker Marcus A, Benlekbir Samir, Rubinstein John L

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Single particle electron cryomicroscopy (cryo-EM) allows for structures of proteins and protein complexes to be determined from images of non-crystalline specimens. Cryo-EM data analysis requires electron microscope images of randomly oriented ice-embedded protein particles to be rotated and translated to allow for coherent averaging when calculating three-dimensional (3D) structures. Rotation of 2D images is usually done with the assumption that the magnification of the electron microscope is the same in all directions. However, due to electron optical aberrations, this condition is not met with some electron microscopes when used with the settings necessary for cryo-EM with a direct detector device (DDD) camera. Correction of images by linear interpolation in real space has allowed high-resolution structures to be calculated from cryo-EM images for symmetric particles. Here we describe and compare a simple real space method, a simple Fourier space method, and a somewhat more sophisticated Fourier space method to correct images for a measured anisotropy in magnification. Further, anisotropic magnification causes contrast transfer function (CTF) parameters estimated from image power spectra to have an apparent systematic astigmatism. To address this problem we develop an approach to adjust CTF parameters measured from distorted images so that they can be used with corrected images. The effect of anisotropic magnification on CTF parameters provides a simple way of detecting magnification anisotropy in cryo-EM datasets.

Для цитирования: Zhao Jianhua, Brubaker Marcus A, Benlekbir Samir, Rubinstein John L. Description and comparison of algorithms for correcting anisotropic magnification in cryo-EM images.. Journal of structural biology. 2015. DOI: 10.1016/j.jsb.2015.06.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.